List of recorded event messages:
Arming
Partial arming
Disarming
Door open
External alarm
Pre-alarm
Tamper
New event
8.4 – ADVANCED MESSAGES PROGRAMMING – A.M.P.
The control panel allows messages (both vocal and SMS) to be sent for a specific event concerning a single detector or the control panel itself,
in a different manner to the default programmed as illustrated in Section D). Once the vocal messages have been recorded and before
confirming (see 8.1 – A.M.P.), the following variations can be performed:
- VOCAL EVENT 1 (2,3, etc.) GROUP AL. A B C. By pressing the numbers 1(A), 2 (B), 3 (C) these alarm zones can be excluded, therefore, a
message will only be sent if the alarm comes from a zone which has not been excluded. When using the configuration with anti-robbery alarm it
is advisable not to transmit vocal messages for alarm zone A (external detectors). It is preferable to first check whether the alarm was an
improper alarm. In the case of confirmed robbery, the request for assistance can be transmitted via remote control or keypad programmed for
the PANIC or ROBBERY function.
- VOCAL EVENT 1 (2,3, etc.) GROUP AL. A B C. By pressing ↑↓ various linked events appear:
TAMPERING AL., 24H PANIC AL., 24H ROBB. AL., 24H TECHN.AL., LOW BATTERY, MAINS FAILURE, PERIODICAL CALL (vocal call to
confirm control panel operating status), TEMPERATURE (internal temperature of the control panel lower than 5°C or higher than 70°C), _ _ _ _
, _ _ _ _ (write event).
If one of the above are confirmed with ↵ , the factory setting is changed and the relative alarm must correspond accordingly.
For example, when one of the programmed vocal messages or SMSs is changed, a call or SMS can be received if a certain event takes place,
such as the opening of a drawer protected by a sensor, on condition that the event is already programmed (e.g. using the word DRAWER).
VOC. EVENT 6 ↑
↵ - - - - - , - - - - - - - ↓
The following events are available to be written (capital letters only) in the first part of the display:
ALARM= alarm
ARM = control panel armed
TAMPER = tamper alarm
Write in the second part the "name" (label) assigned to the detector (A 02, B 04 or "DRAWER" if this name has been used in programming the
detector); to indicate the control panel, write "C.PANEL". For example, by writing DISARM, C.PANEL, the linked telephone numbers will be
called with a vocal message or SMS with every disarming of the control panel.
NO EVENT: By programming a message with NO EVENT, no calls of any kind to the linked numbers will be made.
9.0 -
EXTRAS MENU : PROGRAMMING OF REMOTE CONTROLS, KEYPADS,
DETECTORS AND RELATIVE FUNCTIONING OPTIONS
REMO TECONTROLS
↓
↵ CONFIRM ↓
SILENTRON – made in Italy
Total system arming
Arming of one section of the system (zone A or B or C or A+B or B+C or A+C depending on selections made)
Total disarming of the system
Warning that a protected door or window has been left open.
Alarm of external detectors (does not set off general alarm but only acoustic and/or vocal warnings)
Sound signal which precedes an alarm during an input delay on a control panel of a detector
Warning that tampering with a part of the system has taken place
Indication that something happened during the most recent period in which the system was armed (see event
memory)
In this case, write ALARM in the first part of the display, plus the number;
or the name of the detector in the second part. A phone call will be received
with a vocal message or SMS every time the drawer is opened.
SUPERV = supervision alarm
DISARM = control panel disarmed
TEMPERATURE = hot/cold alarm
KEYBOARD CODES
↵ CONFIRM ↓
SCAN = radio interference alarm
D.OPEN = door open
ARM A/B/C = specific zone armed
↓
ALARM GROUP . . ↑
↵ CONFIRM ↓
COPYRIGHT SILENTRON DS5500/1/2/3BA080228GM
VOC. EVENT 6 ↑
↵ ALARM ,DRAWER ↓
BATT = low battery
END AL = door closed (end of alarm)
EXTRAS↑
↵ CONFIRM ↓
24 H PANIC ↑
↓
↵ CONFIRM ↓
11