(After Electrical Requirements Are Met)

The following removal and installation instructions describe how to remove and
install the IntelliBrite pool and spa light assembly. Also use these instructions
after completing the following light replacement procedure:
Note: For IntelliBrite Spa Light, Face Ring, Uni-Tension Wire Clamp, Gasket and
Lens Removal and Installation instructions, see page 20.
Failure to bring the pool or spa's electrical system up to code requirements
before installing the underwater light will create an electrical hazard which
could result in death or serious injury to pool users, installers, or others due
to electrical shock, and may also cause damage to property.
1 Switch off main electrical switch or circuit breaker, and the
switch which operates the IntelliBrite underwater light.
Do not service the light while in the pool water. The light MUST
be serviced while on the deck.
2.
To remove light fixture assembly from the pool. Remove the special
bronze pilot screw at top of face ring. Remove the IntelliBrite light
assembly from the niche and place it on the deck.
3.
Cut the cord about 12 in (30.5 cm) from the back of the light
assembly.
4.
Remove Junction Box cover, disconnect the light fixture wires, and
pull the cord through the conduit. Tip: Before pulling the cord, tape
the new cord to the existing cord, This might make it easier to
feed the new cord through the conduit (see following step).
5.
Feed the new light fixture cord through the conduit from the niche to
the Junction Box. Note: Depending on the length of the conduit,
special tools may be required to pull the cord through the conduit.
6.
Leave at least 4 ft (1.22 m) of cord to coil around the light fixture; see
Figure 3 on page 8. This allows the light to be serviced on the deck
after the pool is filled with water.
7.
Cut the cord at the Junction Box, leaving at least size 6 in (1.27 cm)
of cord to make connections.
8.
Strip 6 in (15.3 cm) of the outer cord jacket from the cord to expose
the three insulated conductors. B
on the three inner conductors).
off the three conductors. Be careful not to damage the copper
conductor.
Replacing the IntelliBrite
5G Pool and Spa Light Fixture
INTELLIBRITE
e careful not to damage the insulation
Strip a 1/2 in (1.27 cm) of insulation
5G Pool and Spa Lights Installation and User's Guide
®
®