installation

WarninG: RISK OF ELECTRIC SHOCK. Ensure the electricity to the wires you are working on is shut off. Either remove the fuse or turn off the
circuit breaker before removing the existing light fixture or installing the new one.
With power disconnected to the electrical box, remove the existing fixture. Make a sketch of how the current fixture is wired (by wire color)
or mark the wires with masking tape and a pencil so you will know how to properly reconnect the wires to the new LED light fixture.
1
Separating the diffuser shade from
the fixture plate
□ Turn the diffuser shade (B) counterclockwise to remove it
from the fixture plate (A).
A
B
3
Making the electrical connections
FOR MOdELS 54436511 ANd 54437511
□ Connect the hot and neutral (black and white) wires from the fixture plate
(A) to the same color wires from the electrical box.
□ Connect the green wire from the fixture plate (A) to the grounding wire from
the electrical box.
□ If 0-10v dimming circuit is available, connect the purple and gray wires
from the power supply box to the same color wires from the electrical box.
□ If dimming is not desired, wrap the ends of the purple and gray wires with
electrical tape to cover the wire.
□ Cover the wire connections using the wire connectors (AA).
□ Wrap the wire connectors (AA) with electrical tape for a more secure
connection.
□ Position the wires back inside the electrical box.
2
Installing the mounting screws to
the electrical box
□ Screw the mounting screws (BB) directly to the electrical
box.
BB
A
4
installation (continued)
FOR MOdELS 54436511-I ANd 54437511-I
nOTe: For Models 54436511-I and 54437511-I , 0-10v dimming is not available
with the motion sensor installed.
□ Connect the hot and neutral (black and white) wires from the sensor installed
on the fixture plate (A) to the same color wires from the electrical box.
□ Connect the green wire from the sensor installed on the fixture plate (A) to the
grounding wire from the electrical box.
□ Wrap the ends of the purple and gray wires with electrical tape to cover the
wire.
□ Cover the wire connections using the wire connectors (AA).
□ Wrap the wire connectors (AA) with electrical tape for a more secure
connection.
□ Position the wires back inside the electrical box.
4
Attaching the fixture plate to the
BB
electrical box
□ Align the keyholes in the fixture plate (A) with the mounting
screws (BB), allowing the heads of the screws (BB) to come
through the large ends of the keyholes.
□ Rotate the fixture plate
(A) until the heads of
the mounting screws
(BB) slide into the
narrow ends of the
keyholes.
□ Tighten the
AA
mounting screws
(BB) to secure the
fixture plate (A) to
the electrical box.
5
Attaching the diffuser shade
to the fixture plate
□ Position the diffuser shade (B) into the fixture
plate (A).
□ Turn the diffuser shade (B) clockwise to secure
it to the fixture plate (A).
BB
□ Restore power at the electrical panel. Turn on
the light switch to activate the fixture.
A
A
5
Please contact 1-855-384-7754 for further assistance.
AA
A
Sensor
A
B
ETiSSL.com