Warning
Risk of explosion!
Do not smoke, cause sparks or use a naked flame
in the vicinity of batteries.
Arcing can injure the operator or damage the
battery connector.
Ensure that the charging parameters have been
set correctly according to the battery
manufacturer's specification.
Do not use the battery if the battery monitoring unit
or its cabling are damaged.
Use insulated tools designed for working on
batteries.
Only perform charging in a well
ventilated environment.
Acceptance
On delivery, visually check the unit for signs of
physical damage.
Check that delivered parts correspond with the
consignment note. Contact your supplier if
anything is missing, see Contact information.
Description
Access™ BMU installed on the battery
See Fig. 1
1. Positive terminal, battery
2. Cable (red) for powering Access™ BMU and
for the supply of battery voltage
3. Electrolyte level and battery temperature
sensor (black)
4. Access™ BMU
5. Cable (black), negative terminal for powering
Access BMU and for the supply of battery
voltage
6. Negative terminal, battery
Access™ BMU
See Fig. 2
1. Indication of high battery temperature (red)
4
2. Indication of low electrolyte level (red)
3. Indication for the specified time and date
(green)
4. Indication of the network status (green)
5. Not used.
6. Magnetic switch network management
Battery, cross section
See Fig. 3
1. Seal, electrolyte level and battery temperature
sensor
2. Lead probe, electrolyte level and battery
temperature sensor
3. Electrolyte
4. Lead plate, battery
Installation
Warning
Electrolyte is corrosive!
If electrolyte comes into contact with the eye,
damage can occur very quickly.
Rinse the eye immediately and thoroughly for at
least 10 minutes, seek medical attention.
Wear protective equipment such as safety glasses
and gloves to avoid contact with the electrolyte.
Note:
Installation may only be performed by qualified
installers.
Follow the battery supplier's instructions for
handling batteries.
Access™ BMU is solely designed for use with
lead-acid batteries up to 96 V nominal DC voltage.
Consult the manufacturer regarding all other
usage.
Ensure that the Access™ BMU is installed by a
qualified installer in accordance with the
instructions.
Access™ BMU must be well protected against
mechanical damage during daily use, servicing
and maintenance.
Instructions
1. Installation of Access™ BMU (Fig. 1):