UK
1
This pump is (manufactured in a factory
which is quality) certified to ISO 9001, ISO
14001. Installed and used correctly, the unit
will give consistent and reliable service.
device is not designed for
persons
(including
ren) with limited physical, sensory
or mental abilities, or those with
minimal experience and knowledge,
unless they are monitored and are
given the necessary instructions for
using the device, with the help of a
person responsible for their safety.
Monitor children and make sure they
do not play with the device.
2
This device is a pump designed to evacuate
waste water from private dwellings (except
for water coming from WC's).
SANIVITE
®
, SANISPEED
®
and SANIPUMP 2
are designed to handle the waste evacua-
tion from a bath, kitchen sink, dishwasher
and washing machine. Its powerful pump
will deal with every day normal usage.
SANISHOWER® FLAT/ SANIDOUCHE®
FLAT is designed to handle the waste from
a shower and handbasin.
Sanispeed will take the above at a heavier
duty rate of usage.
®
®
SANISHOWER
/SANIPUMP 1
is desig-
ned to take the waste from a shower and
handbasin.
This appliance conforms to EN 12050-2
and the European standards concerning
electrical safety and electromagnetic
compatibility.
3
INSTALLATION
The unit should be installed in the same
space as the connected facilities and
should be accessible for possible service.
The fitting and working of your appliance
must meet local regulations and the EN
12056-4 standard.
To optimise the latest technical develop-
ments concerning soundproofing incorpo-
rated into this unit, it is important to:
• fix the discharge pipe correctly, with
distances of not more than one metre
between the fastenings.
CONNECTION TO THE ELECTRICAL
SUPPLY
should be carried out by a quali-
fied person.
The unit should be connected to a fully
child-
earthed electrical supply. All wiring must
conform to BS7671, 1992 requirements
for electrical installations. The unit requires
a 220/240V single phase AC 50 Hz supply
(UK specification). Do not connect the unit to
a conventional plug and socket. It must be
wired into a fused, unswitched, fixed
wiring connector fitted with a 5 amp
fuse. The wires in the mains lead are colou-
red in accordance with the following code:
Brown - Live
Blue - Neutral
Green/Yellow – Earth
Warning: Ensure the electricity is
turned OFF at the main switch board
before wiring to connector.
All work on cable, pressure chamber
and motor should only be carried out
®
6
IN ALL CASES, YOU MUST DISCONNECT
THE PUMP FROM THE POWER SUPPLY
• The motor does not activate
• The motor intermittently
activates
• The motor operates normally, but
does not stop or continues to run
for a long time
• The unit stops
• Soiled water comes up into
the shower basin (units with
side inlets)
7
GUARANTEE
2 years guarantee as from its date of purchase subject to correct installation and correct use.
caustic, acid or other chemicals into these products.
by a qualified Saniflo servicing agent,
as special tools are required.
4
COMMISSIONING THE
UNIT
Once electrical and plumbing connections
have been made, check that all seals, and
connections are watertight.
Check both the discharge pipework from
the unit and the other sanitary appliances
connections.
5
WARNING !!!
If away for a long period, we recommend
that you turn off the water supply to the
WC served by the unit.
CARE OF YOUR UNIT
In order to remove scale and clean the
pump, use a household descalent (like
SANIFLO Cleanser/descalent).
PROBABLE CAUSES
• The electrical power supply
• Restore the electrical supply
is not active
• The electrical power supply is
• Check the electrical power
defective
supply
• The motor or the control system
• Otherwise, ask an approved
is defective
repair agent to intervene
• The connected sanitary devices
• Check the installation upstream
are leaking
• The non-return valve is faulty
• Clean or replace the non-return
valve
• The length or height of the
• Check the installation
installation is over the
specification, or there are too
many bends/elbows
• The pump cover plate is
• Otherwise, ask an approved
occluded
repair agent to intervene
• The unit has been running for
• Wait for reset, then ask an
too long (thermal cut-out)
approved repair agent to
intervene
• Shower installed too low as
• Check the installation
compared with the pump
• Hinged side inlet discs
• Clean the hinged discs
clogged up
• Otherwise, ask an approved
repair agent to intervene
REMEDIES