7. SPECIFICATIONS
7.1 PUMP SPECIFICATIONS
Max. temperature of liquid
pumped
Max. qty. / max. size of solids
Max. working pressure
Delivery diameter
EN
Suction diameter
* = threading according to ISO 228
7.2 MOTOR SPECIFICATIONS
Type
IP rating
Max. starts per hour
Insulation class and
temperature rise
Type of duty
Ratings
This list shows specification of Ebara motors. In case of using other motors, please
see nameplate of motors and check the motor manufacturer's specification.
7.3 PUMP RATING PLATE
The nameplate is an aluminium label applied to the pump which bears its technical
specifications.
Relevant numbers:
"TYPE" Pump model
"P/N°"
Pump item number
"Hmax" Maximum head
"Hmin"
Minimum head
"Q"
Indicates upper and lower flow rate limits
Indicates head limits corresponding to minimum and maximum
"H"
flow rate
"P2"
Rated power of the motor (output at shaft)
"HP"
Rated power of the motor expressed in HP (Horse Power)
"Hz"
Frequency
"min-1" Speed of rotation
"MEI"
Index of the pump's quality in relation to its efficiency
"Hyd. Eff." Hydraulic efficiency of the pump
14
U.M.
EVMS1-20
EVMS32-90
depends on the mechanical seal
°C
(see Data Book)
Ppm/
50 /
mm
0.1 ÷ 0.25
MPa
1.6 ÷ 2.5
1.6 ÷ 3.0 ÷ 3.5
*
G 1" ÷ Ø 100mm
IC411 - T.E.F.C.
IP 55
IP 56 (only for EVMS1-90 ≥ 15 kW)
N.°
kW
100
≤ 0.55
60
0.75 ÷ 3.0
30
4.0 ÷ 11
15
15 ÷ 30
8
37 ÷ 45
F
(class B for teperature rise)
Continuous S1
see motor rating plate
7.4 INFORMATION ON AIRBORNE NOISE
Power
Motor
[Kw]
size
LpA [dB]* LwA [dB]** LpA [dB]* LwA [dB]**
0.37
71
52
0.55
71
52
0.75
80
52
1.1
80
52
1.5
90
60
2.2
90
60
3.0
100
62
4.0
112
66
5.5
132
68
7.5
132
68
11
160
73
15
160
72
18.5
160
70
22
180
70
30
200
70
37
200
73
45
225
75
The table gives maximum sound emission values for motor-driven pumps.
*
Sound pressure level - Mean value of measurements taken one metre from
the pump. Tolerance ± 2.5 dB.
** Sound power level. Tolerance ± 2.5 dB.
THE MANUFACTURER RESERVES THE RIGHT TO AMEND TECHNICAL
DATA FOR THE PURPOSE OF PRODUCT IMPROVEMENTS AND
UPDATING.
8. PREPARING FOR USE
WARNING!
Installation must be carried out by a qualified engineer.
Free the pump from the packaging and lift it and lower it
with suitable lifting gear in compliance with safety rules.
Note that the motor's lifting hooks are not suitable for
lifting the motor-driven pump.
8.1 COUPLING TO THE MOTOR
The motors to be coupled to the EVMS pumps must meet IEC standards and must
have the preload spring positioned as illustrated:
WARNING!
Required the presence and the installation of the
preload spring as indicated in the drawing above.
50 Hz
60 Hz
–
57
–
–
57
–
–
57
–
–
57
–
–
65
–
–
65
–
–
67
78
–
71
82
79
73
84
79
73
84
84
78
89
83
75
86
81
75
86
81
74
85
81
75
86
84
77
88
86
79
90
1. Load direction
2. Thrust bearing
3. Preload spring