IMPORTANT: Installation must be
carried out according to the manu-
facturer's instructions. Incorrect
installation may cause harm and
damage to people, animals or prop-
erty, for which the manufacturer
accepts no responsibility.
Before carrying out any work on the
electrical section of the appliance, it
must be disconnected from the
mains.
Connection to a good earth wiring
system is absolutely essential.
The manufacturer accepts no
responsibility for any inconve-
nience caused by failure to comply
with this rule.
DETAILS
The hob must be installed by a quali-
fied electrician in line with all electrical
and installation requirements pub-
lished by the Institute of Electrical
Engineers. We recommend that the
appliance is connected by a qualified
electrician, who is a member of the
N.l.C.E l C. and who will comply with
the l.E.E. and local regulations.
Before carrying out the connection to
the power supply, the voltage rating of
the appliance (stamped on the appli-
ance identification plate) must be
checked for correspondence to the
available mains supply voltage, and
the mains electric wiring should be
capable of handling the appliance's
power rating (also indicated on the
identification plate).
This appliance must be connected by
a competent person, using fixed wiring
via a DOUBLE POLE SWITCHED FUSED
SPUR OUTLET (with 3 mm minimum
distance between the contacts).
ELECTRICAL SECTION
for the UNITED KINGDOM
A double pole switch must be provid-
ed no further than 2 metres from the
appliance to the electrical supply. All
supply current and earth conductors
must be able to withstand an ambient
temperature of 75°C.
After having installed the appliance,
the power switch must always be in a
accessible position.
The wires in the mains lead are
coloured in accordance with the fol-
lowing code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live.
As the colours of the wires in the
mains lead for the appliance, may not
correspond with the coloured mark-
ings identifying the terminals in your
spur box, proceed as follows:
1)The wire which is coloured green
and yellow must be connected to
the terminal marked E (Earth) or
or Green coloured.
2)The wire which is coloured blue
must be connected to the terminal
marked N (Neutral), or coloured
Black.
3)The wire which is coloured brown
must be connected to the terminal
marked L (Live), or coloured Red.
DOUBLE POLE SWITCHED
FUSED SPUR OUTLET
FUSE
use a 30 AMP fuse
Fig. 5.1
ON