Cadac SAFARI CHEF 2 Instrucciones Para El Usuario página 4

Ocultar thumbs Ver también para SAFARI CHEF 2:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 53
If there is a leak on your appliance (smell of gas), close the cylinder valve immediately and take
it into a flame free location where the leak may be detected and stopped. If you wish to check for
leaks on your appliance, do it outside. Do not try to detect leaks using a flame; use soapy water.
The correct way is to smear the joints e.g. where the stem fits into the cylinder, with soapy water.
If bubbles form, then there is a gas leak. Immediately turn off the gas supply by closing the
control valve on the gas container and then the appliance valve. Check that all the connections
are properly fitted. Re-check with soapy water.
If a gas leak persists, return the product to your CADAC dealer for inspection / repair.
Use Outdoors Only.
3. Assembly Instructions
WARNING: The legs are spring loaded. Opening and closing of the legs must
be done in a controlled manner to avoid personal injury or damage to your
Safari Chef 2.
To open the legs, turn the unit upside-down and hold the legs down while lifting each leg
individually (Fig. 4c). You will hear a "click" if the leg(s) has located correctly (Fig. 4a).
To fold the legs back, securely hold the leg and push the leg release clip down (Fig. 4b). Then
push the legs in-ward to its closed position (Fig. 4c). This needs to be done sequentially to
optimize space. First the right front leg (1), then the left front leg (2), and lastly the rear leg (3)
(as seen in Fig. 4d).
Before connecting the gas supply, firstly check that the appliance valve is in the off position by
turning the control knob fully clockwise (See Fig. 2).
I 3B/P (30), I 3+ (28-30/37) and I 3B/P (37) Appliance categories: Fit the Valve Tailpiece onto
the Valve (Fig.5) by screwing it on in an anti-clockwise direction. Push an 8mm inside diameter
Hose onto the Valve Tailpiece until it is properly seated. On the other end attach a suitable
30mbar low-pressure (I 3B/P (30) and I 3+ (28-30/37) Butane configurations) or 37mBar low-
pressure regulator (I 3+ (28-30/37) Propane configuration), again making sure that the hose is
well seated. The hose used must comply with BS 3212 / SABS 1156-2 or equivalent.
I 3B/P (50) Appliance category: Screw a Hose with the correct threaded fittings on each end,
onto the left hand ¼"BSP thread of the Valve. Attach a suitable 50mbar low-pressure regulator
on the other end of the hose. The hose used must comply with DIN 4815 part 2 or equivalent.
Note: The hose and regulator are not supplied with the appliance. For details, contact your local
stockist.
The hose length should be no less than 800 mm and shall not exceed 1.5 m. Check the expiry
date on the hose and replace when necessary or when national conditions require it. Do not twist
or pinch hose.
Your appliance is now ready for use.
Fig. 4a
Fig. 4c
Fig. 4b
Fig. 4d
2
OFF
28-30 & 37mbar
ONLY
GB
Fig. 1
Fig. 2
Fig. 3
Fig. 5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

6540l16540l0

Tabla de contenido