SI T E P R E PA R AT I ON

Electrical Requirements

Installation must comply with all applicable electrical codes.
The electrical supply must be located within the shaded
area shown in the illustration and chart below. A separate
circuit servicing only this appliance is required. A ground
fault circuit interrupter (GFCI) is not recommended and may
cause interruption of operation.
The electrical outlet must be positioned with the grounding
prong to the right of the thinner blades.
CAUTION
The outlet must be checked by a qualified electrician
to be sure it is wired with the correct polarity. Verify the
outlet is properly grounded.
WARNING
Do not use an extension cord, two-prong adapter, or
remove the power cord ground prong.
EL EC T R IC A L R EQ UI R EM ENT S
Electrical Supply
Service
Receptacle
EL EC T R IC A L S U PP LY L OCAT I O N
18" Model
24" Model
30" Model
LEFT SIDE
OF OPENING
1
4
/
"
A
2
(114)
1
4
/
"
4
(108)
FLOOR
1
1
/
/
"
"
4
4
(6)
(6)
Electrical supply location
115 VAC, 60 Hz
15 amp dedicated circuit
3-prong grounding-type
A
6"
(152)
9
1
/
"
(241)
2
12
1
/
"
(318)
2
H OM E SEC U R ITY C ON N E CT IO N
If the unit will be connected to a home security system, low-
voltage leads must be provided to the unit. Two connectors
are located behind the top trim. Provide 10'
lead wires for each connector, exiting the back wall near the
electrical receptacle.
Remove the top trim by disengaging the trim from the hinge
side of the unit. Rotate the trim and remove the trim pin from
the handle side vertical support. Refer to the illustrations
below. Use spade terminals or wire nuts to make proper
wiring connections. Refer to the following color codes:
Normally open contacts—white with red stripe wire.
Common—gray with white stripe wire.
CAUTION
The alarm circuit in the unit is intended as a low-
voltage, low-current device only. It should not be used
to switch line power. Any unused terminals should be
completely insulated and all wires should be secured
away from conductive or moving components.
Top trim—hinge side
minimum
(3 m)
PIN
Top trim—handle side
subzero.com | 5