Vertical Shift (V-SH)
Vertical Amplitude (V-AM)
Vertical Slope (V-SL)
Horizontal Phase (H-PH)
Horizontal Amplitude (H-AM)
East/West Parabola (EW-P)
East/West Upper Corner (EWUC)
East/West Lower Corner (EWLC)
East/West Trapezium (EW-T)
Horizontal PArallelogram (H-PA)
Horizontal BOW (BOW)
- Set BLANKING to 1. Adjust V-SH until the blanking is at the vertical centre of the
screen. Set BLANKING to 0.
- Adjust V-AM so that the picture fi ts at the top.
- Adjust V-SL so that the picture fi ts at the bottom.
- Adjust H-PH to the correct centering of the picture.
- Adjust H-AM to the correct width of the picture.
- Adjust EW-P to the correct geometry at the sides. The middle part of the vertical
lines must be as straight as possible.
- Adjust EWUC to the correct geometry at the upper corners.
- Adjust EWLC to the correct geometry at the lower corners.
- Adjust EW-T to the correct geometry.
- Adjust H-PA to the correct geometry.
- Adjust BOW until the vertical lines at both sides of the picture are straight.
It may be necessary to repeat some of the adjustments.
- Press GO to store the adjustments.
Exit Service Mode.
Adjustments, English
9.18