Fry top gas
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 52
Pilot burner goes out during use
Possible causes:
Insufficient gas supply pressure.
Defective gas tap or valve.
Defective thermocouple or insufficient heating.
Thermocouple incorrectly connected to gas tap or valve.
Knob of gas tap or valve not pressed sufficiently.
The main burner does not light (even though pilot is lit)
Possible causes:
Insufficient gas supply pressure.
Blocked tubing or nozzle.
Defective gas tap or valve.
Defective burner ( gas outlet holes clogged ).
Heating cannot be adjusted.
Possible causes:
Defective gas tap or gas valve.

16. REPLACING COMPONENTS

REMINDERS FOR REPLACING COMPONENTS

After replacing a gas system component, check for gas
leaks at connection points.
GAS FRY-TOP
Replacing the gas tap / valve gas tap.
Remove the control panel.
Remove and replace the component.
Re-assemble all parts. For assembly, proceed in reverse
order.
Replacing the burner, the pilot burner, the
thermocouple, the piezoelectric ignition and the igniter.
Remove the control panel.
Remove and replace the component.
Re-assemble all parts. For assembly, proceed in reverse
order.
GAS FRY-TOP WITH TAP
Replacing the gas tap.
• Remove the control panel.
• Remove and replace the component.
• Re-assemble all parts. For assembly, proceed in reverse or-
der.
Instructions for maintenance
Replacing the burner, the pilot burner, the thermocouple,
the piezoelectric ignition and the igniter.
• Remove the control panel.
• Remove and replace the component.
• Re-assemble all parts. For assembly, proceed in reverse or-
der.
GAS FRY-TOP WITH VALVE
Replacing the gas valve and safety thermostat.
• Remove the control panel.
• Remove the bulb from its seat on the bottom of the hotplate.
• Remove and replace the component.
• Insert the bulb properly in its seat on the bottom of the hotpla-
te.
• Re-assemble all parts. For assembly, proceed in reverse or-
der.
Replacing the burner, the pilot burner, the thermocouple,
the piezoelectric ignition and the igniter.
• Remove the control panel.
• Remove and replace the component.
• Re-assemble all parts. For assembly, proceed in reverse or-
der.

17. CLEANING THE INTERIOR

Check the condition of the inside of the appliance.
Remove any built-up dirt.
Check and clean the fumes exhaust system.
18. MAIN COMPONENTS GAS FRY-TOP WITH TAP
Gas tap
Main burner
Pilot burner
Thermocouple
Igniter
Piezoelectric ignition
Safety thermostat
GAS FRY-TOP WITH VALVE
• Gas valve
• Main burner
• Pilot burner
• Thermocouple
• Igniter
• Piezoelectric ignition
• Safety thermostat