Troubleshooting - Tractel volt trac 250 Manual De Empleo Y De Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 78
Hoist
GB
Problem
The hoist will not operate
Operates in one direction
Poor rotation of lifting motor with
muffled noise
Jamming of the load chain
26
9� Troubleshooting
Possible cause
Main cut off switch off
Emergency stop activated
Power supply cut
Electrical limit switch activated
Limit switches inoperative
Fuse inoperative
Contacts on transformer or pendant
control protection fautly open
thermal protectior
Power supply phases reversed
The motor after heavy use is too
hot and the thermal cut out is
triggered
Electrical limit switches damaged
Contactor coil burnt out or open coil
Faulty power supply
Significant voltage drop
Electromagnetic brakes does not
open
Faulty gearbox
Overload
Faulty friction clutch
Loss of one phase
Distortion or twisting of the chain
inside or improper alignment with
entry guide
Snagging of the slack chain
around an obstacle
Actions
Set it to "on" position
Deactivate the emergency stop
Check all the electrical connections
Move the chain using the button
box in the opposite direction.
Call in an approved engineer
Change the fuse and check the
electrical connections
Call in an approved engineer
Have an electrician change the
electrical power supply
Secure the area under the load and
wait for the hoist to cool
Call in an approved engineer
Call in an approved engineer
Check the supply voltage
Check that voltage is correct and
there is no overload
Check the brake set and call an
approved workshop. See the
volt trac™ annual safety and
maintenance inspection manual.
Call in an approved engineer
Check and reduce the load
Call in an approved engineer
Call in an approved engineer
Stop operation immediately
Contact supplier or an approved
service shop
If the load is suspended, take up
the load with another device which
provides the equivalent safety, and
remove the load from the hoist.
Try to release the chain, and if
not, send the hoist to an approved
service shop
The slack chain MUST be freed
before resuming operation

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Volt trac 500Volt trac 1000Volt trac 2000

Tabla de contenido