Installation
Structural Rough-Ins
Mounting for Standard ADA and TAS height shown.
Points A, B, and C require sufficient backing compliant with
local building codes.
WARNING Ensure bowl is completely seated in
the wall bracket and securely fastened
to the wall at point A.
33½"
(851)
31½"
(800)
29⁵⁄₈"
(753)
Bottom of
Bracket
CODE
A
Install (1) ³/₈" wall anchor with a minimum pull-out force of 1,000 lb per local codes at locations shown
B
C
Install wall anchor with a minimum pull-out force of 100 lb per local codes at locations shown
S
S1
*
Measured from center of top slot on access panel bracket
RIM HEIGHT
33½"
30½"
Bradley • 215-1842 Rev. H: ECO 20-08-028B
10" (254)
5"
(127)
Wall Bracket
A
B
13¼"
(337)
5½"
(140)
28"
(711)
C
Access
Panel
Bracket
12⁵⁄₈" (320)
DESCRIPTION
Provide structural backing compliant with local building codes.
#10 Wall Anchors for Soap Control Box Bracket
#10 Wall Anchors for Soap Tank Bracket (100 lb pull out)
VERTICAL HEIGHT ADJUSTMENTS
No Adjustment
Subtract 3"
Secure bracket to wall using min.
anchor bolt to the left of C/L and min.
anchor bolt to the right of C/L. The anchor
bolt to the right of C/L must be min. 5"
apart from the anchor bolt to the left of
C/L. When mounting is complete, check
to ensure the bracket is level. See Step 1:
Bracket Mounting for more information.
10" (254)
C
L
2½"
(64)
S
S
2¼" (57)
S1
S1
9¹⁄₈" (231)
9¹⁄₈" (231)
12⁵⁄₈" (320)
Finished Floor
10" (254)
A
B
C
15³⁄₈"*
(390)
Access
Panel
Bracket
FIXTURE STYLE
Standard Height ADA, TAS, and CSA
Juvenile ADA and TAS
1/21/2021
LVQD1
³/₈
"
"
³/₈
(mm)
25¼"
(654)
QTY.
2
2
4
2
2
11