Attach Power Line Filter; Control Box And Valve Installation - Bradley Verge LVQ Serie Manual Del Usuario

Sistema de lavabo con tecnología washbar
Ocultar thumbs Ver también para Verge LVQ Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
10

Attach Power Line Filter

A
Secure dryer power line
filter to underside of
bowl using (2) #10 x ³/₈"
screws provided.
11

Control Box and Valve Installation

A
Secure control box to
underside of bowl using
(2) #10 x ³/₈" long screws
provided.
Attach ¹/₄" supply tube from the
WashBar to the ¹/₄" supply valve
outlet. Loosen the compression
B
nut on the valve body. Push
the ¹/₄" supply tube firmly into
the tube connector until it is
fully seated. Hand tighten the
compression nut.
For thermostatic mixing valve installation, secure ¹/₂" supply
hose to hot water supply valve inlet. Secure the other supply
hose from cold water supply to cold water supply valve inlet.
C
Secure valve to bowl using (2) #10 x ³/₈" long screws and
washers (install washer between the bowl and valve bracket).
For tempered line installation, secure ¹/₂" supply hose to
tempered water supply and TL valve inlet (not shown).
Secure valve to bowl using (2) #10 x ³/₈" long screws and
washers (install washer between the bowl and valve bracket).
Bradley • 215-1842 Rev. H: ECO 20-08-028B
Hot
Cold
Cold Supply/
Hot Supply/
Stop Valve
Stop Valve
Remove ³/₈" compression nut/sleeve from the hot
D
and cold supply stop valves. Connect ³/₈" end
of flexible supply hose to ³/₈" compression on
supply stop valve. Ensure hot and cold supply
hoses are connected to hot and cold supply stop
valve. For TL option, only connect cold supply.
1/21/2021
¹/₄" Water Supply
Outlet with
Compression Nut
³/₈"
Compression
Nut
LVQD1
19

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Verge lvqd1

Tabla de contenido