Software Update - Bradley Verge LVQ Serie Manual Del Usuario

Sistema de lavabo con tecnología washbar
Ocultar thumbs Ver también para Verge LVQ Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

LVQD1
Setting the LED Lights ON (Bright) / ON (Low) / OFF for Standby/Idle Mode
To set the LED lights to ON (Bright) / ON (Low) / OFF for Standby/Idle Mode, while in Configuration Mode:
1. Hold hand under water sensor for 5 seconds to start the selection process. Selection options will cycle until hand is
removed.
2. Continue to hold hand under water until desired setting color is shown then remove hand while color is being displayed.
• Blue LED (Bright): standby LEDs ON (default when WashBar is reset)
• Blue LED (Low): Standby LEDs slightly dimmer
• LED Off: standby LEDs OFF
Setting Motor Speed
To set the dyer motor speed, while in Configuration Mode:
1. Hold hand under dryer for 5 seconds to start selection process. Selection options will cycle until hand is removed.
2. Continue to hold hand under dryer until desired setting color is shown then remove hand while color is being displayed.
• Red LED: High Speed (default when WashBar is reset)
• Blue LED: Medium Speed
• LED Off: Low Speed
Reset Mode
Reset mode is when the user can reset all WashBar settings back to their default settings. This removes all custom configuration
options but does not reset counters. Counters cannot be reset. All of the sensors (soap, water, dryer) are active in this mode.
Once the WashBar has been reset, it will automatically return to Standby/Idle Mode.
To reset the WashBar:
1. Place a hand under the dryer and then immediately (within 1 second) under the soap sensor and hold hands under both
dryer and soap sensors for approximately 20 seconds until all LED lights turn solid green.
2. Remove hands once all LED lights turn solid green. WashBar has now been reset and will return to Standby/Idle Mode. If
foam soap is being used, the soap type will need to be set to foam. If this step is not done, the low soap indicator will not
be accurate. See Configuration section "Setting the Soap Type."
LED lights may flash and cycle different colors. To reset the WashBar, only remove hands once all LED lights are solid
green.
24 Hour Water Purge
If water has not been used within 24 hours, the WashBar will automatically run water for 5 seconds. This is not configurable by the user.

Software Update

Software revisions can be found at
www.bradleycorp.com/software-updates/washbar
The master control board software can be updated using a USB flash drive. To
update the software:
1. Download the desired software revision into the ROOT directory of a USB
flashdrive (do not copy file in any folder).
2. Place the USB flash drive containing the desired software into the master
control board. Disconnect the barrel plug to power off. Then reconnect the
barrel plug. Wait a few seconds for the control box to restart.
3. DO NOT REMOVE FLASH DRIVE until status LED on master control
board turns off and LED lights on WashBar turn all BLUE to indicate
update is complete.
LEDs may turn off after ALL have flashed BLUE if standby LED setting is set to "OFF". RED LEDs may be solid if low
soap or board error has occurred or Flashing RED if sensor is blocked.
4. Remove USB flash drive if desired. Leaving USB flash drive in master control board will not affect WashBar performance.
Software version will display on the LCD screen. Software can be reversed to a previous version by having only an
earlier version of the software on the USB flash drive.
26
1/21/2021
LCD Display
Status LED
Bradley • 215-1842 Rev. H: ECO 20-08-028B
Installation
USB Port

Publicidad