Installation

Master Control Box

Scan to watch maintenance and
troubleshooting videos for the WashBar!
12V 2A
Barrel Plug
Sensor Board 1
Connector
Sensor Board 2
Connector
LED Board
Connector

System Startup

Before providing power to WashBar, make sure the area under the WashBar is clear of any obstructions and that sensors
are clear.
The first time the WashBar is powered up, there is a sequence of LEDs that will light up.
• Within 5-10 seconds of receiving power, the WashBar will cycle it's LED lights RED, GREEN and then BLUE. Once
the LEDs turn blue, the WashBar is in Standby/Idle Mode.
If any of the WashBar LEDs flash RED, check for sensor obstruction. Once obstruction is removed or cleaned, the
WashBar LEDs will return to blue indicating that the WashBar is in Standby/Idle Mode.
• The power LED on the master control box will be GREEN indicating the unit has power.
Bradley • 215-1842 Rev. H: ECO 20-08-028B
6V Power LED
Over Current LED
Proximity Cable (USB
1.1 Mini B, Female)
LCD
Status LED
USB Connector
Soap Cable
Water Valve Cable
Dryer Cable