120-240VAC Models

To wire the Ex d VAC flameproof beacon:
See Figure 7 on page 15. Connect the line (hot) power source wire
a.
to the terminal block screw marked L1 on the PCB.

Figure 7 IN/OUT PCB connections for Ex d 120-240VAC

Connect the neutral (common) power source wire to the terminal block
b.
screw marked L2.
Connect the ground wire to the terminal block clamp marked GND.
c.
Insert the PCB into the enclosure and fully tighten the PCB captive screw.
5.
Place the cover on the housing and tighten it by turning it clockwise.
6.
To ensure O-ring compression, the cover must be fully seated against the
7.
housing when the threads are tightened. Turn the M3 set screw on the side
of the housing until the screw contacts the housing.
Ensure that the unused wire entries are sealed with the provided brass
8.
M20-1.5 x 6 g stopping plug (equipment-certified).
Test the beacon for proper operation.