Specific Conditions of Use:
1.
The Modular Visual LED has external non-metallic surfaces which may
provided a potential electrostatic charging hazard.
See the manufacturer's instructions for further information.
2.
The Modular Visual LED has metallic components in the non-metallic
walls of the enclosure which can store electrical charge and therefore may
provide a potential electrostatic charging hazard. The metallic brass inserts
have a capacitance of 14 pF. The metallic guard has a capacitance of 18
pF. See the manufacturer's instructions for further information.
cULus Zone Certifications:
Models that contain the Ex e increased safety (E-box) are not cULus Zone
certified and not suitable for use in Class, Zone locations. Only the following
models are certified: G-LED-DC-D-x, G-LED-DC-T-x, G-LED-AC-D-x, and
G-LED-AC-T-x. Please disregard any references to the E-box when using these
instructions for Class, Zone locations.
These models use protections:
Class I, Zone 1, AEx db IIC T3
Zone 21, AEx tb IIIC T3/200°C IP66 (Tamb= -55°C to +70°C)
Ex db IIC T3
Ex tb IIIC T3/200°C IP66 (Tamb= -55°C to +70°C)
Unpacking the Beacon
EXPLOSION HAZARD: A damaged lens can lead to explosions, causing
serious injury or death. If a lens is damaged, it must be replaced.
After unpacking the beacon, examine it for damage that may have occurred
in transit. If it has been damaged, do not attempt to install or operate it. File a
claim immediately with the carrier, stating the extent of the damage. Carefully
check all envelopes, shipping labels, and tags before removing or discarding
them. Disposal of all shipping materials must be carried out in accordance with
national and local codes and standards. If any parts are missing, please call
Federal Signal Customer Support at +1 708-534-4756 or +1 877-289-3246.
Creating Combination Fixtures in the Field
The Federal Signal Global Series Ex de products can be connected together
in the field using interchangeable E-box end caps and a proprietary coupling
system. The proprietary coupling system allows for simple and cost effective,
wiring from product to product, often eliminating the need for expensive Ex
wiring practices and Ex rated glands.
Model G-LED Global Series LED Beacon
Installation and Maintenance Instructions
7