Bomba de transferencia de combustible, de uso industrial, a prueba de explosión, 15gpm (57l/minuto), 12v, dc

Publicidad

Idiomas disponibles

Idiomas disponibles

WETTED MATERIALS: Precision Cast Iron, High Performance Powdered Metal (PM), FC-208; Nylon (NYL); Nitrile
Rubber (Buna-N/NBR) and Ryton
Polyphenylene Sulfide (PPS)
®
Materials (Can be Pumped): Gasoline, Diesel, Kerosene & Mineral Spirits Only.
SAFETY FIRST
FOR YOUR OWN PROTECTION READ, UNDERSTAND AND OBSERVE
WARNING
THESE SAFETY TIPS AND ALL INSTRUCTIONS BEFORE USING THIS PRODUCT!
Your Safety is very important to us. To ensure operator safety and to protect the pump from potential damage,
you must be fully acquainted with this instruction manual before performing any operation. Please read this
Operational Manual carefully. The Instructions contained in this Manual must be read and understood by the
operator prior to operating the pump. It is extremely important that you read the entire Manual to become
familiar with the pump before you begin to operate the unit. Properly cared for, this pump will give you extended
time of trouble-free performance. Please store this Operational Manual, for later reference.
Equipment Misuse Hazard: It is the responsibility of the installer to provide the necessary line accessories
to ensure the correct and safe operation of the pump. The accessories that are not suitable to be used with the
previously indicated material could damage the pump and/or cause injury to persons, as well as causing pollution.
Caution: The pump must never be operated before the delivery and suction lines have been connected.
Pumps should only be used as recommended. Any tool can fail if it is misused. To avoid Serious Personal
Injury when using your Pump, follow these Safety Tips and Rules :
• Do Not use Pump for the purpose it is not intended for.
• Always Wear Appropriate Protective Clothing and Equipment. Do Not wear Loose Clothing or Jewelry.
They can be caught in Moving Parts. Protective Gloves and Non-skid Footwear are recommended when
working with Pumps. Approved Guards and Protective Equipment, such as, Impact Resistant Safety Glasses,
Safety or Chemical Splash Goggles, Full Face Shield, Safety Shoes, Arm Guards, Protective Gloves and Apron
Must be used for Operator Protection. Wear Protective Hair Covering to contain Long Hair.
• Use Respirator. Always wear proper Face Mask to avoid Inhalation of Fumes and Hazardous Gases.
Never Smoke near any fluids that are to be pumped. Always Pump in a well ventilated area.
• Stay Alert. Watch what you are doing. Use Common Sense. Do Not operate Pump when you are Tired
or under the influence of any medications. Be Alert at All Times, especially during Repetitive, Monotonous
Operations. You may have demonstrated a certain product hundreds of times, but do not be lulled into
Complacency due to a False Sense of Security. Tools can be extremely unforgiving if not used carefully and
as per instructions.
• Do not Over-reach. Keep Proper Footing and Balance at all times.
• Keep Visitors Away. All Visitors should be kept away from Work Area. Do Not let Visitors operate Pump.
• Check Damaged Parts. Before use of the Pump, carefully check for any Damaged Parts to determine that
the Pump will operate Properly and Perform its intended function. Check for Alignment of Moving Parts, Binding
of Moving Parts, Breakage of Parts, Mounting, and any other Conditions that may affect its Operation. Any
Part that is damaged should be properly Repaired or Replaced by an Authorized Service Center.
• Maintain Pumps with Care. Keep Pumps Clean and regularly serviced or maintained for Better and Safe
Performance. Follow Instructions for Lubricating and changing Accessories. Inspect Pumps Periodically and
if Pump or any of its parts are Damaged - have it Repaired by an Authorized Service Facility. Always keep
your Pumps Inspected and Replace Immediately, if damaged or Worn.
• Store Idle Pump. When not in use, Pumps should be Stored in Dry, High and/or in Locked-up place.
Childproof the Pump and work area.
• Pumps Must only be repaired by Qualified Technicians.
2
• Always check local area Laws and Ordinances regarding Handling, Pumping and Disposing of Liquids.
Dispose of pumped fluid properly. Do Not drain into Street Drains, House Drains, or Backyards.
Contact your local Municipal Waste Management officials for proper disposal methods.
If there is any question about a condition being safe or unsafe, do not operate the pump.
SPECIFICATIONS
• Voltage: 12VDC
• Motor Amps: 20A
• Flow Rate: 15 GPM (57L/Minute)
• Max. Suction Lift: 5 ft. (1.5M)
• Speed: 2400 RPM
• Self-Priming: >5 ft. (1.5M) above Liquid Level
• Inlet Connection: 2" Male on Tank Adapter
1" on Female on Pump
• Inlet & Outlet Diameter on Pump: 1" NPT
To ensure Safe and Efficient Operation, it is essential to Read, Understand and Follow each of these
Warnings and Precautions:
• DO NOT Smoke near Pump or use Pump near an open Flame. Fire could result.
• Disconnect Power to Pump before Servicing Pump.
• Turn-Off the Switch before Connecting Power.
• Take Motors needing Service to an Authorized Repair Shop or Return to Factory to Maintain.
• A Filter should be used on Pump Outlet to ensure that no Foreign Material is transferred to Fuel Tank.
• Tank or Barrel should be anchored to prevent Tipping whether it is either Full or Empty.
• The Pump Motor is equipped with Thermal Overload Protection. If overheated, it will Shut itself OFF
without any damage to the Windings. Move ON/OFF Lever to the "OFF" Position to reset Pump.
Preliminary Inspection: Verify that all components are present. Request any missing parts from Lumax.
• Check that the Pump has not suffered any Damage during Transport or Storage.
• Carefully clean the Suction and Delivery Inlets and Outlets, removing any dust or other packaging material
that may be present.
• Check that the Electrical Data corresponds to those indicated on the Data Label.
• Always install in a well illuminated area.
Positioning and Configuration: In the case of installation in the open air, proceed to protect the Pump by
providing a protection roof.
Note: The Pump can be installed in any position (Pump Axis, Vertical or Horizontal). The Pump must be
secured in a stable way using the holes on the bed of the motor and vibration damping devices.
Note: The broad range of Pump accessories make it suitable for many different uses, installations and
applications. The supporting base can be positioned in different ways.
• Power: 180W
• On/Off Switch
• Continuous Duty Cycle: 30 Minutes
• Max. Total Head: >20 ft. (6M)
• Work Pressure: 18 PSI (1.2 Bar)
• Built-in Bypass Valve
• Power Cord: 16 Ft. (5M)
• Maximum Liquid Temperature: 104°F (40°C)
• Weight: 32 lbs. (14.5kg)
3