Gree GMV-S120WL/A-S Manual Del Propietário página 37

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Content
symbol
Division
symbol
Indoor unit
and outdoor
unit can't be
L
matched with
each other
Indoor
Setting of
capacity DIP
d
switch code
is abnormal
E
Current
sensor of
F
compressor 2
is abnormal
Water flow
J
switch
protection
Drop
protection for
top
b
temperature
Outdoor
sensor of
compressor 1
Malfunction
of driven
current
P
inspection
circuit of
compressor
Malfunction
of driven
H
current
inspection
circuit of fan
Master indoor
unit setting is
U
succeeded
Debugging
Malfunction
type
of no master
unit, which is
C
not displayed
by indoor unit
Cooling
A
Status
Cooling only
n
unit
Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.
C
L
Malfunction of
water flow switch
Malfunction of air
outlet temperature
sensor
Current sensor of
compressor 3 is
abnormal
Protection because
high pressure is too
low
Drop protection for
top temperature
sensor of
compressor 2
Protection because
the voltage of
driven DC bus bar
of compressor is
too low
Protection because
the voltage for
driven DC bus bar
of fan
Emergency
operation DIP
switch code is
wrong
Rated capacity
ratio is too low
Auto
refrigerant-charging
Target low pressure
correction
E
Rotation speed
Malfunction
of EC DC water
of shunt
pump is abnormal
valve setting
Malfunction
Malfunction of
of upper
indoor CO2 sensor
water
temperature
sensor
Current
Current sensor of
sensor of
compressor 4 is
compressor 5
abnormal
is abnormal
Oil return
Oil return pipe is
pipe is
blocked
leaking
Malfunction
Malfunction of inlet
of outlet tube
tube temperature
temperature
sensor of
sensor of
condenser
condenser
Malfunction
Inverter
of driven
compressor is
charging loop
phase-lacking
of
compressor
Malfunction
Inverter fan is
of driven
phase-lacking
charging loop
of fan
Invalid of
refrigerant charging
Malfunction
because
there's
multiple
master units
Manual
Air supply
refrigerant-charging
Negative code
Fan type
32
F
J
Setting of
Zero
function DIP
crossing
switch code
malfunction
is wrong
of PG motor
Malfunction
of floor
Malfunction
heating
of backwater
water inlet
temperature
pipe
sensor
temperature
sensor
Current
sensor of
Malfunction
compressor 6
of DC motor
is abnormal
High
pressure
and low
pressure
sensor are
connected
reversely
Failure
AC current
startup of
protection for
inverter
inverter
compressor
compressor
Failure
AC current
startup of
protection for
inverter fan
inverter fan
Malfunction
Address DIP
because
switch code
there's
of system is
multiple
shocking
master wired
controller
Startup
Alarm for
debugging
cleaning the
confirmation
filter
of unit
High
Defrosting
temperature
temperature
prevention
adjustment
when heating
value
P

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Gmv-s140wl/a-sGmv-s160wl/a-s

Tabla de contenido