3. Wiring diagram
Wire the device using the wiring diagram shown below.
(see section 5, Switch Configuration when using more then one device)
4. Single Connex-02 Installation
4.1
Before installation find required lift signals (e.g. Out of Service, Lift Maintenance)
4.2
Install Connex-02 in close proximity to the lift signals for ease of wiring and use
DIN rail provided in kit or existing for fixing. See section 10 for removal instructions if
required.
4.3
Connect the 4 wire J8 'CAN' DCP to the Connex-02 CAN 'IN' for HUB
communication.
4.4
Once DCP 'CAN' connection is made to the Connex-02 MK CAN IN, wire the lift
signals as required to the input/output (see Section 5 'Input & Output for further
details).
3