AVIRE Connex-02 Guia De Instalacion página 4

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Additional steps for multiple Connex-02 installation...
4.5
Depending on the location of the lift signals required, two Connex-02 can be used
via CAN IN and CAN OUT this links one device to another (see section 2 installation
figure C)
4.6
Using more then one device on a 'CAN' line will require EOL (End Of Line) to be
configured (see section 6 Switch Configuration 6.3)
5. Inputs & Outputs
5.1 Inputs
There are 5 opto-isolated inputs available on Connex-02 which must be driven from an
external 10 – 30VDC supply with a switching voltage between 4 and 8 volts. The input
voltage is rated 12VDC at 3mA max or 30VDC at 7mA max; inputs can be configured as
normally OPEN or normally CLOSED using the Avire Hub.
Configuration of inputs & outputs must be made using the Avire Hub.
5.1.1 Input from External Sources - Any lift signal
Each of the 5 inputs within Connex-02 is designed to accept any
type of signal from any external source such as Out of Service, Lift
in Maintenance, Doors open/close or any other signal. The installer
must identify a suitable signal at the specified rating before wiring.
The functionality of each input can be defined using the Avire Hub
which is explained in section 9.
5.1.2 Technician on Site - Measure service engineer arrival and
departure
The "Technician on Site" push button is available separately and
is pre-wired for plug and play which can be used in any of the 5
inputs.
Product Part Number
MC-ART01-200-0-00-000
Configure an automatic time out on the Avire Hub so the technician
on site input is automatically disabled after a pre-determined amount
of time (please refer to section 9.2.1.2 "Technician on Site set up" for
more information)
It is also possible to reset this input remotely on the Avire Hub
(please refer to section 9.2.1.2 "Technician on Site set up" for more
information)
To change connectors or confirm wiring, please consult the table
below:
Corresponding Number
1
2
3
4
Product Description
"Technician on Site" push button
Wiring colour
Brown
Green
White
Yellow
TO ANY N/O or N/C