Oximo 50 S auto RTS
8.2.2 Sun disappearing
If the sunlight level is below the set threshold on
-
the Sunis RTS sensor, the roller shutter will be
raised to the upper end limit after a delay of 15
to 30 minutes (except if the roller shutter is in the
lower end limit position).
9. Problems with the motor?
9.1 Questions and answers
Problems
The roller shutter is
not operational.
The Oximo 50 S auto
RTS motor turns in
one direction only.
The Oximo 50 S auto
RTS motor is attached
to the wrong side of
the roller shutter.
The roller shutter
mounting on the
roller tube must be
modified.
The favourite position
has shifted.
60
Possible causes
The wiring is incorrect.
The Oximo 50 S auto RTS motor
is hot.
An incorrect cable has been used.
The control point battery is weak.
The control point is not compatible.
The control point used is not program-
med into the Oximo 50 S auto RTS
motor.
There is radio interference.
The Oximo 50 S auto RTS motor is
too close to the its end limit positions
or to the last obstacle encountered.
The installation of the Oximo 50 S
auto RTS motor does not meet requi-
rements for the site.
The bolts are incorrectly affixed.
The travel of the roller shutter has
been changed.
Check the wiring and modify it if
necessary.
Wait for the Oximo 50 S auto RTS
motor to cool.
Check the cable used and ensure it
has: 3 leads.
Check whether the battery is weak
and replace it if necessary.
Check for compatibility and replace
the control point if necessary.
Use a programmed control point or
program this control point.
Turn off all radio equipment nearby.
Press the up or down buttons on the
control point to unlock the Oximo 50 S
auto RTS motor.
Fit the Oximo 50 S auto RTS motor on
the other side of the roller tube, restore
the Oximo 50 S auto RTS motor to its
original settings and start complete
Oximo 50 S auto RTS motor instal-
lation again as set out in the section
entitled "Installation".
Modify the installation (position of the
bolts), restore the Oximo 50 S auto
RTS motor to its original settings and
start complete Oximo 50 S auto RTS
motor installation again as set out in
the section entitled "Installation".
Waiting for the automatic retiming
at the end of several cycles or start
complete Oximo 50 S auto RTS motor
installation again as set out in the
section entitled "Installation".
Copyright © 2008 Somfy SAS. All rights reserved.
Installation guide
Solutions