10. Light Kit Assembly.
Re-attach molex plugs, connect BLACK wire from
motor housing to BLACK wire from LED light kit and
WHITE wire from motor housing to WHITE wire from
LED light kit. Be sure that molex connections snap
together completely.
Carefully arrange wiring within the motor plate. Align
slotted holes in the LED light kit with loosened screws
in motor plate--be careful not to pinch wires or molex
connections between the LED light kit and the motor
plate. Twist LED light kit to lock. Re-insert screw
previously removed (Section 9). Tighten all 3 screws
to secure LED light kit.
Locate grooves on glass shade and align with nodules
on inside of LED light kit. Push up gently on glass
shade. Turn glass shade in a clockwise direction until it
slides into place.
11. Wall Control Operation.
The wall control is operational for fan
light
(dimmer).
12. Testing Your Fan.
It is recommended that you test fan before
finalizing installation. Slide the knobs to OFF
position on wall control. Restore power from circuit
box. Test light and dimmer function and then test
fan speeds. If fan and/or light do (does) not function,
please refer to "Troubleshooting" section to solve
any issues before contacting Customer Service.
Turn fan completely off before moving the reverse
switch. Set reverse switch to recirculate air
depending on the season:
- LEFT position in summer (diagram 1)
- RIGHT position in winter (diagram 2)
A ceiling fan will allow you to raise your thermostat
setting in summer and lower your thermostat
setting in winter without feeling a difference in your
comfort.
Important: Reverse switch must be set either
completely LEFT or completely RIGHT for fan to
function. If the reverse switch is set in the middle
position (diagram 3), fan will not operate.
and
Move slide knob
up or down for
LIGHT brightness
reverse switch
diagram 1
page 8
motor
housing
LED light kit
glass shade
motor housing
reverse switch
diagram 2
diagram 3
LOW speed
MEDIUM LOW speed
MEDIUM speed
HIGH speed
turns fan OFF