WHEN IN THE "RUN" SCREEN
PRESS THE ENTER KEY TO ACCESS: (LEFT KEY)
PRESS THE BACK KEY TO ACCESS: (RIGHT KEY)
PRESS AND HOLD THE BACK KEY TO ACCESS:
PRESS THE HIDDEN KEY UNDER THE EPRO LOGO TO ACCESS:
— MENU —
CHANGE DISPLAY
CHANGE DISPLAY
UP/TGTQ
DWN/TQ
— MENU —
CAL CORRECT
TQ: 000.0
NEW TQ: 000.0
— MENU —
LOCK OUT
LOCK OUT
UP/OFF
DWN/ON
— MENU —
REHIT STATUS
REHIT
UP/OFF
DWN/ON
— MENU —
CYCLE DELAY
CYCLE DELAY
DELAY: 02500
Power Source ..................... Universal 100 - 240 VAC, 50 - 60 Hz
Pneumatic Source .............. min 50 scfm @ 6 bar pressure (87 psi)
Inputs/Outputs .................... Opto isolated and relay dry contacts; up to 48vdc/120 vac/10 amps with screw lug terminals
Error Proofing .................... OK/NOK for acceptable cycles vs REHIT/CROSS THREAD, STRIP/SLIP OFF, CYCLE ABORT & BATCH
COUNT STATUS
Serial Port ........................... RS 232 port; standard DB connector (date/time/Pset#/TgTq/TQ/COUNT/OK-NOK)
Interface .............................. Two Line 0.44" LCD backlit (16) Character per line
Four-button keypad (Up, Down, Menu & Reset/Reverse)
Sixteen (16) tri-color LED Fastener COUNTING STATUS indicators
Eight (8) LED Parameter/Application set indicators
BATCH STATUS OK / NOK lights
OVERRIDE button; one touch for full power - no control reverse; hold down for Batch clear/reset.
Ethernet (optional) ............. Separate IP address with buffered memory provides asynchronous network communication.
Supports standard WINDOWS based TCP/IP (10baseT) protocol. Connector is female RJ-45.
DeviceNET (optional) ......... (4) or (8) Byte packet selectable. Supports both 'polled' and 'change of state' communication.
Power Supply (optional) .... 24 VDC isolated and independent for Device NET requirements or to provide powered I/O
Device NET NOTE: Grounding is per single network standard with shield connected to "V-" terminal
to prevent ground loop noise.
Humidity ...................... 0 - 95% non condensing
Temperature ............... 0 to +50 degrees Celsius (32 - 122 F)
"RUN" MENU
This option will change the display to read the measured ACTUAL TORQUE when a transducer
is connected to the controller.
"CAL CORRECT" is used with "DYNAMIC" programming and the torque reading doesn't agree
with whatever method the plant is using to check the joint. Simply enter the torque value from the
audit device into the "NEW TQ: XXX.X" line. This will change the reading to agree with the torque
audit device.
Activating the "LOCK OUT" will render the ENTER key inoperable. This will prevent the operator
from having access to the programming functions. The ability to change between parameter sets
and to override (for continuous reverse operation) remains.
Use this option to disable the REHIT error function. This will disable error indication on a REHIT
but slip/strip and early cycle abort will remain enabled. (10039 code only)
NOTE: DISABLING REHIT WILL ALLOW THE COUNTING OF DOUBLE-HIT FASTENERS.
This setting will determine the "off" time between the end of one run-down and the resetting of
the tool for the next cycle. A default value of 02500 will keep the tool off for about one (1) second
prior to allowing the operator to press the trigger for the next fastener. If this is too slow, adjust
(by using the UP/DWN buttons) the value down to approximately 1000-1200. Any lower may be
too quick and may not allow the operator enough time to release the trigger. A higher value will
cause the tool to reset slower.
SPECIFICATIONS
OPERATING CONDITIONS:
10039.7.16 & 10041.7.16
TgTq: XXX
PSET 01
COUNT: 00/XX
OK
— MAIN MENU —
PARAMETER SETUP
— OVERRIDE —
UP/OFF
— BATCH RESET —
UP/YES
DWN/NO
Weight .............................. approximately 4 kg. (10 lbs.)
Dimensions ...................... 8" wide X 12" high X 6" deep
7