EN
6.1 - WIRE ROLLERS AND GUIDES
CONTROLS
1.
Digital voltmeter and ammeter
2.
Wire feed speed adjustment
ܟProvides continuously variable wire feed speed control. The
wire speed is directly proportional to welding current so that
increasing the wire speed increases the current and vice- versa.
3.
2T/4T switch
4.
Recall A/V
Push on the key "Recall" allows to see the last parameters
used (I/U) after welding.
5.
Central European connector
ܟAllows an easy connection to the welding torch simultaneously
carrying power, torch button connection, gas and liner
connections.
6.
Connecting Gas Hose
7.
Connecting Weld Cable
MAINTENANCE
8 - EN