A1 TECHNICAL DATA
EH model
Fan coil application
Cooling capacity MIN/NOM/MAX (1)
Nominal cooling capacity (1) (*) EN 14511:2018
EER EN 14511:2018 (1) (*)
ESEER EN 14511:2018
Heating capacity MIN/NOM/MAX (2)
Nominal heating capacity (2) (*) EN 14511:2018
COP EN 14511:2018 (2) (*)
Application radiant
Cooling capacity MIN/NOM/MAX (3)
Nominal cooling capacity (3) (*) EN 14511:2018
EER EN 14511:2018 (3)
Heating capacity MIN/NOM/MAX (4)
Nominal heating capacity (4) (*) EN 14511:2018
COP EN 14511:2018 (4) (*)
Sound pressure (5) (∆)
Sound power (6) (∆)
Scroll compressor
Fans
Heat exchanger water content
Heat exchanger nominal flow water side (1)
Residual head (P0 installation) (1)
Amount of R410A refrigerant
Total oil charge of compressors
Electrical data
Absorbed power in summer mode NOM (1) (●)
Absorbed power in winter mode NOM (2) (●)
Absorbed power in summer mode NOM (3) (●)
Absorbed power in winter mode NOM (4) (●)
Pump absorbed power (P0)
Electrical power supply
Auxiliary power supply
Nominal current
Maximum current (■)
Pump absorbed current (P0)
Dimensions
Width (L)
Height (H)
Depth (P)
Water connections
(1) Under the following conditions: condenser
inlet air temperature 35°C; chilled water
temperature 7°C; temperature differential at
evaporator 5°C.
(2) In the following conditions: evaporator
inlet air temperature 7°C B.S., 6°C B.U.; hot
water temperature 45°C; temperature
differential at evaporator 5°C.
(3) Under the following conditions: condenser
inlet air temperature 35°C; chilled water
temperature 18°C; temperature differential at
evaporator 5°C.
(4) In the following conditions: evaporator
inlet air temperature 7°C B.S., 6°C B.U.; hot
water temperature 35°C; temperature
differential at evaporator 5°C.
ALLEGATI / ENCLOSED DOCUMENTS / ANNEXOS / ANLAGEN / ANEXOS
(5) Sound pressure level in dB(A) referring to
a 5 m distance from the unit, in directionality
factor equal to 2.
(6) Sound power level in dB(A) on the basis
of measurements taken in accordance with
UNI EN-ISO 9614 and Eurovent 8/1
Standards.
(■) Current drawn by the compressor and
fans.
(●) Power absorbed by the compressor and
fans.
(*) The data according to EN14511 refer
staging P0.
86
EH1819
kW
8,3/16/17
kW
16,2
2,98
5,15
kW
6,8/18,0/19,1 10,1/24,6/27,2
kW
17,7
3,32
kW
11/20,1/21,2
14,5/27,5/29,3 15,7/31,7/32,6
kW
20,3
3,90
kW
7,5/19,1/20,1
9,7/25,3/27,9
kW
18,8
4,10
dB(A)
46
dB(A)
72
Scroll regulated by inverter
n° x kW
2x0,3
l
1,5
l/h
2800
kPa
89
Kg
2,73
Kg
1,22
kW
5,37
kW
5,3
kW
5,14
kW
4,55
kW
0,3
V-ph-Hz
V-ph-Hz
A
12
A
16,5
A
1,37
mm
1522
mm
1280
mm
600
Ø
1 ½"
(∆) With accessory SIL, the value decreases
by 2dB(A).
ESEER (European Sesonal EER) European
seasonal average efficiency.
EH2519
EH3019
12/23,5/24,8
12,8/26,7/27,8
23,8
27,0
2,84
2,97
4,75
4,70
10,7/28,8/31
24,3
28,5
3,26
3,28
27,8
32,0
3,87
3,89
10,2/29,4/31,6
25,0
29,1
4,10
4,10
48
49
74
75
2x0,3
2x0,3
1,9
1,9
4000
4600
89
76
3,75
4,45
1,48
1,48
8,39
9,10
7,5
8,7
7,19
8,20
6,12
7,1
0,3
0,3
400-3+N-50
230-1-50
15
15
23,9
23,9
1,37
1,37
1522
1522
1280
1280
600
600
1 ½"
1 ½"