PROBLEM
Motor doesn't run
Motor "hunts"
Motor runs at "full speed"
uncontrollable
Motor rotates in wrong direction
Motor stalls under a light load
If a newly installed control will not operate, it is likely that a terminal or connection is loose. Check to make sure connections
are secure and correct. If the control is still inoperative, go to www.dartcontrols.com/support or call (317) 873-5211.
INPUT VOLTAGE
12 - 48 VDC ± 15%
12 - 48 VDC ± 15%
12 - 48 VDC ± 15%
12 - 48 VDC ± 15%
Load current (continuous)
Speed adjustment
Speed range
Overload capacity
Current limit
Current limit output
Acceleration
Deceleration
Maximum speed
Minimum speed
Power Connections (P1)
Signal Connections (P2)
Speed regulation
Operating temperature
Package configuration
Internal operating frequency
IN CASE OF DIFFICULTY
POSSIBLE CAUSE(S)
• Incorrect or no power
• Speedpot set at zero
• Worn motor brushes
• Current limit set too low
• Max trimpot set too high
• I.R. Comp. trimpot set too high
• Loose speedpot connections
• Min. or Max. trimpots not properly adjusted
• Possible control failure
• Motor armature hooked up backwards
• Current limit trimpot improperly adjusted
MODEL SELECTION
OUTPUT VOLTAGE CONTINUOUS CURRENT CONTROL TYPE MODEL NUMBER
0 to Input voltage
0 to Input voltage
0 to Input voltage
0 to Input voltage
SPECIFICATIONS
65E10 / 65E10E
10 amps
5K Ohm potentiometer or 0 to +10VDC input signal
adjustable 100% to 200% of full motor load, up to 200% of control current rating
Euro-style terminal block (14 Ga. to 28 Ga.)
1% of base speed via adjustable IR Compensation trim pot
-30
10 Amps D.C.
10 Amps D.C
ENCLOSED
20 Amps D.C.
20 Amps D.C.
ENCLOSED
30 : 1
200% for 10 seconds; 150% for one minute
Up to 50 VDC at 0.3 A
adjustable - 0 to 10 seconds
non-adjustable - 0.5 seconds
adjustable - 50 to 100% of base speed
adjustable - 0 to 30% of max speed
Euro-style terminal block (10 Ga. to 14 Ga.)
Euro-style terminal block (14 Ga. to 28 Ga.)
0
0
0
C to +60
C (-22
F to +140
0
0
0
-15
C to +60
C (5
F to +140
black anodized aluminum extrusion
approximately 18kHz
9
CORRECTIVE ACTION
Install proper service
Rotate speedpot fully CW
Replace motor brushes
Adjust current limit trimpot CW
See "Trimpot Adjustments"
See "Trimpot Adjustments"
Secure all connections
See "Trimpot Adjustments"
Send to Dart Controls, Inc.
Reverse armature + and - leads
See "Trimpot Adjustments"
CHASSIS
65E10C
65E10E
CHASSIS
65E20C
65E20E
65E20 / 65E20E
20 amps
0
F) for Chassis.
0
F) for Enclosed.