DO NOT REVERSE POSITIVE AND NEGATIVE BATTERY LEADS. THIS WILL DAMAGE THE CONTROL.
TO CHANGE MOTOR DIRECTION, INTERCHANGE THE POSITIVE AND NEGATIVE ARMATURE LEADS.
Refer to the wiring diagrams below for proper connection of DC Voltage, Armature, and Speedpot wiring to the control.
To properly adjust the CURRENT LIMIT setting, a DC ammeter should be placed in series with the armature line. This meter
can be removed after the control is adjusted.
Min Speed
Max Speed
Accel
IR Comp.
Current Limit
HOOK-UP DIAGRAMS
CAUTION !!
TURN POWER OFF WHILE MAKING CONNECTIONS.
65E10/20 HOOK-UP DIAGRAM
12V Relay Coil
IN4001 thru 4007
Current
Limit Trip
Inhibit (P2-5)
Output
Common (P2-4)
Pot Low (P2-3)
Pot Wiper (P2-2)
Pot High (P2-1)
-Arm (P1-4)
+Arm (P1-3)
+Battery (P1-2)
-Battery (P1-1)
WARNING:
Optional
Inhibit
(see hook-up
below)
P2
-5
-4
-3
Orange
-2
Red
-1
White
-4
-3
-2
-1
Fuse
P1
4
5KΩ
Speedpot
Motor
Customer
supplied
SPST switch
+
or relay
Battery
-
-
+