Lightning Protection

As per the stipulations of Lightning Protection Standard EN 62305 Parts 1-4, the system must not be connected to the building's
A safety gap of at least 1 metre from any adjacent conductive object must be maintained. In the case of installations on top
General Important System Information
The system is a two-circuit system. The system forms a closed circuit (process water circuit) with the heat exchanger of the stor-
age tank. This circuit is completely separate from the solar circuit (storage tank). The system offers appropriate performance only
when installed in frost-free areas. If the temperature falls below 0 °C for more than 18 consecutive hours or -5 °C for more than 6
consecutive hours, the system must be drained.
In this system, an electric immersion heater can be installed into the solar water circuit. The system
SYSTEM-E
storage tank is already prepared for its installation as standard. An appropriate electric immersion
The hot and cold water lines in the process water circuit are not protected from freezing by the electric
immersion heater. When installing, appropriate insulation and trace heating for the pipes must be
provided.
The frost tolerance limits are based upon an assumed set of environmental conditions. Extended periods of cold weather,
er's responsibility to protect the system in accordance with the manufacturer's instructions if the air temperature is anticipated to
Appropriate insulation or pipe heat tracing must be provided on-site to prevent the hot and cold water pipes from freezing.
However, this condensation disappears after a few hours of sunlight.
A thermal mixer, where the required water temperature can be set, must always be installed at
the hot water outlet as scald protection. The safety over-pressure valve provided must be
installed on the cold water connection to the system in order to limit overpressure in the water
circuit.

System Alignment

For the installation of the system, a suitable place without shading (e.g., trees, buildings) is required throughout the year. The opti-
mum function of the system will be obtained if the system is installed pointing south in the northern hemisphere as far as possible
mounted in the horizontal orientation, please note the appropriate installation instructions (see Page x).
System Inclination
The system is suitable for an inclination of at least 5° to a maximum of 45° and may only be mounted horizontally (+/-5°). Other
installation angles as cited are not permitted, as this will cause irreparable damage to the solar storage tank.
System Pressures
The maximum operating pressure in the cold water supply must always be limited to 10 bar; if necessary, a corresponding / suit-
openings above (see sketch) must not be closed as this will cause irreparable damage to the solar storage tank.
valve provided must always be installed in the relevant connection on the storage tank to limit the overpressure in the process
water circuit (see sketch).
6
30°
EN
20°
5-45°