Connection Diagram:
Connections, Joints and Piping
Depending on the application, the system can reach temperatures of up to 95 °C, which can lead to injuries (e.g., scalding).
As a result, a suitable thermal mixer must always be installed downstream of the hot water outlet to limit the process water tem-
perature to max. 60 °C.
withstand temperatures of at least 100 °C.
Connections and Piping
The system must be connected to the connection piping (3/4"
Please pay special attention to the hydraulic diagram for the cold water and hot water connections in the manual.
When the connections are tightened up, pliers or other wrenches must be used for holding (locking), in order to prevent the
System Circuit Pipe Insulation
The pipes must be insulated with a suitable UV-resistant material in order to reduce heat loss and protect the pipes from freezing.
Make sure that the valves are not insulated to ensure perfect functionality. The process water connection must be established in