TROUBLESHOOTING, CAUSES, SOLUTIONS
Troubleshooting
1
The indicator
blinks rapidly.
2
The indicator
blinks slowly.
3
The indicator
is on.
Indicator
stays on even after pressing
4
button.
5
Indicator
flashes.
6
Indicator
stays on.
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported
GYSFLASH 1.12 PL
Causes
• Polarity reversal
• Battery voltage is too high
• Clamps in short-circuit
Battery out of order or very low voltage. Change the battery.
Failure during charging, battery not
recoverable.
Thermal protection
Charger in sleep mode.
Charge interrupted by pressing
Solutions
• Check that the clamps are correctly connected
• Check that it is a 12 V battery.
Change the battery and press
charge.
Ambient temperature is too high (>50°C), cool the
room and let the charger cool down.
Press button
or connect a battery to the char-
ger to exit sleep mode.
.
Press
again to restart the charge.
EN
to restart a
11