WARNING
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse box before wiring. All wiring
must be in accordance with National and Local codes
and the ceiling fan must be properly grounded as a
precaution against possible electrical shock.
7.1
This Control is designed to operate only One Ceiling
Fan.
Before disconnecting Power, ensure that the Fan is set
at the Highest Speed.
NOTE: Electric connections should be in
accordance with the National Electrical Codes and
all Local Codes. Before starting, disconnect power
to the circuit at the fuse box or circuit breaker
panel.
Remove the Faceplate and Screws from the Existing
Wall Switch. Pull Switch out from Wall Outlet Box.
Disconnect the Wire from the Existing Fan Wall Switch
(Figure 21).
7.2
Slide the Fan Control to the OFF position (0).
Connect one BLACK wire from the Fan Control to
the facility active BLACK wire with a wire connector
(provided) (Figure 22).
Connect the other BLACK wire from the Fan Control to
the outlet box active BLACK wire with a wire connector
(provided with control) (Figure 22).
NOTE: Use wire connectors (supplied) to secure
electrical connections.
7. Installing the Wall Control
Figure 21
TO NEUTRAL
Figure 22
Please contact 1-800-654-3545 for further assistance
15
SWITCH
FACEPLATE
TO FAN MOTOR LOAD
BLACK
BLACK
4
3
BLACK
2
1
0
BLACK
emersonfans.com
U.L. Model No.: CF765-1
WALL
OUTLET
BOX
TO
120VAC
SOURCE
HOT