RP 340 Press Tool
RP 340 Diagnostic Codes
LED
Status Description
Green
Glows
Tool ON.
Blinks
Out of acceptable voltage range
— Tools using a battery: Replace battery with a fully charged battery.
— Tools using an AC Power Adapter: Connect tool to a reliable voltage supply.
Red
Glows
Out of temperature range 15°F (-10°C) to 122°F (50°C).
Blinks
Jaws mounting pin not fully engaged. Insert pin.
Yellow
Glows
Service indicator after 40,000 cycles. NOTE: Tool will lock after 42,000 cycles.
Blinks
Machine is locked – Service after 42,000 cycles or after a malfunction.
12
If using extension cord, use 16 AWG for 50' or less, 14 AWG for 50' to 100'.
Icon