W I R I N G SYS TE M
Compressor station
Functions and features.
This is an electronic device which has the function of piloting the motor of the compressor and
carrying out all the controls and electrical protection of the system .
Its main features are as follows:
a) Protection of the battery through automatic turning off of the compressor when the feeding
voltage reaches the minimum threshold.
The compressor will start up again automatically when the voltage goes back to normal values.
VOLTAGE
b)
Amperometric protection in case the compressor should fail to start up .
This generally happens when the pressures do not have time enough to balance themselves
again.
Should this kind of protection come into action, the compressor will carry out a 1 minute pause
and will then start up again automatically.
Wiring connections
The wiring connection (Figure 5) must be made complying with the following instructions:
1) Feed the refrigerator with direct current coming from a battery (12 or 24 Volt.).
Do not feed it with equipment which does not provide the maximum guarantee of continuity,
such as transformers or other instruments.
2) Use cables having a suitable cross section (see the table) to feed the refrigerator. If possible,
they should be without any joints on the leads which could cause voltage drops.
NOTE. Using cables of a wrong cross section could stop the compressor even if the battery is
charged.
CABLE CROSS
SECTIONS
MM
3) Make sure the polarity is right (+ Red / - Black).
4) The fridge is supplied with a 15A fuse kit..
TABLE OF THE VOLTAGES AT WHICH
THE BATTERY SAVER COMES INTO ACTION
BATT ERY SAV ER VOLTAGE
STOP
12V
Volt 10,4
24V
Volt 22,8
M AXI M UM L ENGT H IN
2
2,5
2,5
4
4
6
6
10
10
START UP AGAIN
Volt 11,7
Volt 24,2
M ET RES
12 V
24 V
5
8
12
20