Manual Operation - Seitron TCD01B Manual Del Usuario

Cronotermostato digital a baterías
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 44
When an electro-thermal actuator is wired to the output, this
parameter must be set with the actuator's travel time, otherwise
'on' pulses of a lower time respect to the travel time would generate
unuseful output actions.
The parameter can be set in the range 3 .. 15 minutes.
The device leaves the factory with parameter set on 3 minutes.
dFLt
'
' SET DEFAULT DATA
With this parameterit ispossible to resetuser parametersin order
tobring back all theparameters to thefactory defaults.
Proceed as follows:
1. Select the parameter 'dFLt' and press 'OK'; the device
automatically sets the default data and the display will show
' -dF- '.
2. To quit the user parameter settings press the ' OK ' button or wait
10 seconds without pressing any key.
3. To reset the normal operation press the ' ' button.
WARNING!
Restoring the Default Data will reset all settings made by the
user, such as Time Program, Heating/Cooling, Set-Points and
all other programmable data.
SHUTDOWN - ANTI-FREEZE FUNCTION
To switch off the timer thermostat press '
The display will show the word 'OFF' and the '
If the timer thermostat was set in the heating mode, the antifreeze
function will be enabled and the '
display; in such a case the room temperature will be controlled
according to the programmed antifreeze temperature set point.

MANUAL OPERATION

Pressing the '
' button will cause the '
on the display and the timer thermostat will control the room
temperature according to the current comfort mode setting selected
by means of knob ' ', 24 hours a day, irrespective of the position
of the dipswitches.
To revert to operation according to the set daily program, press
' again.
'
TEMPERATURE / TIME DISPLAY
By repeatedly pressing the key '
the current time, the room temperature measured by the internal
sensor, explained with the icon '
measured by the remote sensor (if wired) explained with the icon
'
'.
The values of temperature displayed are shown adjusted with the
set Offset value.
In case the parameter ' rEG ' is set on ' EHt
sensor is not wired or is broken the display will show the words
' SEnS OPEN ' or ' SEnS SHrt ' with the icon '
20
'.
' symbol.
' symbol will appear on the
' symbol to appear
' the display cycles on showing
', and the room temperature
' but the remote
' turned on.

Publicidad

Tabla de contenido
loading

Productos relacionados para Seitron TCD01B

Tabla de contenido