CPV..-GE-ASI-8E8A-...
3.2 Connecting sensors (PNP inputs)
Use cable type KM8-M8-GSGD-... and plugs with union nuts,
thread M8x1, for connecting sensors.
Fasten the plugs with the aid of the union nuts in order to pre-
vent unintentional loosening (e.g. due to vibration). Seal unused
sensor connections with the protective caps supplied. Only then
can you comply with protection class IP65.
PLEASE NOTE
The inputs are protected against short circuits. If a short
circuit occurs, the slave will be switched off. The master
regards this slave as missing. When the short circuit has
been eliminated, the slave responds immediately as being
operative.
1
0
1
2
3
1
2
Inputs of the first AS-Interface address (n)
3
Inputs of the second AS-Interface address (n+x)
4
Pin 1: 24 V
5
Pin 2: input E(n+x)+3
Pin 3: 0 V
18
4
2
4
5
6
7
5
3
9907NH