DIP switches on the bottom of the sub-base:
2
1
2
DIP switch 1: valve slots 1 to 4 (slave 1)
DIP switch 2: valve slots 5 to 8 (slave 2)
Set the DIP switches as follows (permitted valve combinations
see 3.6):
Valve locations 1 to 4 or 5 to 8
2 double-solenoid valves *) 4 single-solenoid valves
Valve slots (1 to 4 / 5 to 8 ): valve type
1/5: Double-sol. valve *)
1/5: Single-solenoid valve
2/6: Reserve/isol. plate
2/6: Single-solenoid valve
3/7: Double-sol. valve *)
3/7: Single-solenoid valve
4/8: Reserve/isol. plate
4/8: Single-solenoid valve
*) Valve plates with 2 valve solenoid coils (e.g. 2 single-solenoid valves,
double-solenoid 5/2-way valves or 5/3-way valves)
24
1
1 double-solenoid valve *),
2 single-solenoid valves
1/5: Double-sol. valve *)
2/6: Reserve/isol. plate
3/7: Single-solenoid valve
4/8: Single-solenoid valve