Type
Protection class (as per DIN 40050)
Temperature:
– operation
– storage/transport
Electromagnetic compatibility
– interference emission
– resistance to interference
Protection against electric shock (protection
against direct and indirect contact as per
EN 60204-1 / IEC 204)
AS-Interface bus connection
– voltage range
(protected against incorrect polarity)
– residual ripple
– max. current consumption at -5° C
– all inputs supply 0-signal
– all inputs supply 1-signal, no current
consumption by sensors (e.g. switches)
– all inputs supply 1-signal, max. current
consumption by sensors
Load voltage connection
– rated value
(protected against incorrect polarity)
– residual ripple
– current consumption for 8 valves
– when switched on (26.4 V)
– when switched on (20.4 V)
– after current drop (stationary; 26.4 V)
– after current drop (stationary; 20.4 V)
1
) e.g. 30 mA per input, incl. 7 mA for input circuit
2
) for max. 30 ms, all valve coils switched simultaneously
9907NH
CPV...-GE-ASI-8E8A-Z M8
IP65 (fully mounted)
- 5° to + 50° C
- 20° to + 70° C
– tested as per EN 55011,
limit value class B
– tested as per EN 50295
By means of PELV power
units (protected extra low
voltage)
DC 26,5 V ... 31,6 V
≤ 20 mVpp
CPV10-... CPV14-...
40 mA
96 mA
278 mA
278 mA
1
)
DC 20.4 V ... 26.4 V
4 Vpp
CPV10-... CPV14-...
2
)
200 mA
310 mA
2
)
160 mA
210 mA
70 mA
100 mA
90 mA
120 mA
40 mA
96 mA
25