CPX type continued
Digital outputs
Rated load voltage
Design
Protection against incorrect
polarity
Output current per channel
Short circuit protection
Voltage drop at output
Switch−off delay
Signal change 0" to 1"
Signal change 1" to 0"
Parallel switching of outputs
for increased performance
Protection against reverse
voltage
Limiting the inductive
switch−off voltage of
connected coils/solenoid
valves
Electrical isolation
Inputs
Outputs
between the channels
to U
EL/SEN
Isolation
Festo CPX−EA 0705c English
−8DE−8DA
8 outputs as per IEC 1131, 24 V
V
OUT
Positive logic (PNP)
Yes
max. 0.5 A (12 W lamp load), no
total current limitation
Yes (electronic),
Response threshold> 0,5 A
1 V
With ohmic load:
< 200 s
< 200 s
Yes, max. 4 outputs (A0 ... A3 or A4
... A7) of the same module
Max. U
OUT
Typical −16 V
none
none
Yes, with intermediate supply or
interlinking block type CPX−GE−EV−Z
(M18), CPX−GE−EV−S−7/8−5POL,
...−Z−7/8−5POL or ...−Z−7/8−4POL
Tested using 500 V DC
29