Warning
Use only power units which guarantee reliable electrical
isolation of the operating voltage as per IEC/DIN
EN 60204−1 Observe also the general requirements for
PELV power circuits as per IEC/DIN EN 60204−1.
Use a closed−loop power unit.
S
To avoid electrostatic discharges and comply with
S
protection class IP54: Seal unused connections with
the protective caps supplied.
To guarantee proper function: Connect the SFC−DC
S
only with the following cables (observe max. length):
Cable
Power supply cable
Motor cable
Control cable
... for reference switch
Programming cable
Festo P.BE−K−SFC−DC−IO 0503NH English
Accessories type ...
KPWR−MC−1−SUB−15HC−...
KMTR−DC−SUB−15−M12−...
KES−MC−1−SUB−15−...
e.g. type SME−10.../SMT−10... or extension
cable type KM8−M8−...
KDI−MC−M8−SUB−9−...
Length [m]
2,5 / 5 / 10
2,5 / 5 / 10
2,5 / 5 / 10
2,5
21