Operation
Output Indicator
The green LED output indicator light comes on when the
generator is operating normally.
Overload Alarm
The red LED overload alarm light flashes when near an
overload and is steady if you overload the generator. The
green output indicator light will also go off. If the generator
was overloaded, you must turn off all electrical loads, then
push the generator reset button to continue operating.
Parallel Operation
Two Briggs & Stratton inverter generators can be run
in parallel with a Briggs & Stratton parallel operation kit
(optional equipment).
See the parallel operation kits instruction sheet for detailed
instructions on installation and operation of the connected
generators.
NOTICE
• Turn electrical loads OFF and disconnect from both
generators.
• The QPT switch must be in the same position on both
generators.
• Connect the parallel cables to both generators before
starting the engines. See instruction sheet supplied
with parallel kit.
• Start engine on one of the inverter generators
according to Generator Start Up.
• Once the green LED output indicator light on the first
generators is steady, start second generator.
• Connect and turn on electrical loads to the parallel
panel receptacles.
• DO NOT disconnect parallel cables after engines
have been started.
• Shut down engines as described in Generator
Shutdown.
10
QPT (QUIET POWER TECHNOLOGY)
This feature is designed to greatly improve fuel economy.
When QPT is on, engine speed increases as loads are
connected, and decreases as loads are removed.
When QPT is off, engine will run at full governed speed.
BRIGGSandSTRATTON.COM