5) PARAMETERS, LOGICS AND SPECIAL FUNCTIONS
In the tables hereunder the single functions available in the control unit are shown.
MENU
Automatic closure time. It is activated only with "TCA"=ON logic.
TCA
At the end of the preset time, the control unit controls a closure operation.
Motor operating time. The total stroke time in the motor opening and closing phases is adjusted.
TM
With the ENC:ON logics, this value is automatically preset by the parameter self-adjustment
procedure (AUTO).
The space covered by the dooe leaf during braking in the opening phase is adjusted. 0 = braking
is disabled.
Tsmo
The value is expressed in percentage on the aggregate value of the stroke.
With ENC:OFF logics the value is expressed in seconds. Braking after the triggering of the limit
switch is adjusted.
The space covered by the dooe leaf during braking in the closing phase is adjusted.
0 = braking is disabled.
Tsmc
The value is expressed in percentage on the aggregate value of the stroke.
With ENC:OFF logics the value is expressed in seconds. Braking after the triggering of the limit
switch is adjusted.
Pso
The torque applied to the motor during braking in the closing phase is adjusted.*
Psc
The torque applied to the motor during braking in the opening phase is adjusted *
The activation time of the service light is adjusted.
TLS
With parameter :0, the area light function is activated. The light is switched on when the motor is
moving and during the TCA dwell time. The light switches off when the motor stops.
The triggering threshold of the anti-crash device (Encoder) during the normal speed phase.*
SEAV
99: maximum sensitivity - 0: minimum sensitivity
The triggering threshold of the anti-crash device (Encoder) during braking.*
SEAR
99: maximum sensitivity - 0: minimum sensitivity
The operating mode of the auxiliary output to terminals 19/20 is preset. See wire connections in
figure 2.
0: output configurated as SCA (open gate indicator light): Off with closed door, on with open
door, slow flash during opening, rapid flash during closing.
AUX
1: output configurated as radio channel II integrated receiver.
2: output configurated as PHOT TEST (photocell test).
3: output configurated as flashing light.
4: output configurated as service light additional to the light on the geared motor. Its activation
time is adjusted by TLS parameter.
MENU
The automatic closure is enabled or disabled
TCA
On: enabled automatic closure
Off: disabled automatic closure
The multi-flat function is enabled or disabled.
On: enabled multi-flat function. The P.P. (Step-by-step) impulse or the impulse of the transmitter have
IbL
no effect in the opening phase.
Off: disabled multi-flat function.
The operating mode of "P.P. Push button" and of the transmitter are selected.
PP
On: Operation : OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Forewarning flashing light enabled or disabled.
On: enabled forewarning flashing light. The flashing light is activated 3 s before the starting of the
PRE
motor.
Off: disabled forewarning flashing light.
The lock function in the closing phase is enabled or disabled.
blc
On: Lock function is enabled.
Off: Lock function is disabled.
During the TCA time, the blinker is enabled or disabled.
ltca
On: Activated blinker.
Off: De-activated blinker.
5.1) PARAMETERS (PAR)
FUNCTION
* WARNING:
An incorrect setting of these parameters may cause danger.
Please comply with regulations in force!
5.2) LOGIC (LOG)
FUNCTION
MIN-MAX-(Default)
MEMO
1-240-(40s)
2-180-(60s)
0-10-(0%)
0-99-(0%)
30-99-(50%)
30-99-(50%)
0-240-(60s)
0-99-(0%)
0-99-(0%)
0-4-(0)
ON-OFF-
MEMO
(Default)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)
(OFF)