GiBiDi F 12 Rally Manual Del Usuario página 16

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 46
16
UK
TRIMMER OPERATION COUPLED TO CN3
MOTOR 1 CURRENT
RV1
LIMITER
MOTOR 2 CURRENT
RV2
LIMITER
WARNING: Current limiter adjustment is also controlled by jumper CN3.
CN3 OPEN
Current limiter adjustment varies from 2.5A to 5.5A
CN3 CLOSED
Current limiter adjustment varies from 3A to 7,5A (Recommended for GiBiDi operators FLOOR 812)
DEFAULT SETTINGS: trimmers adjusted to half-stroke and CN3 open.
LED SIGNALLING
The LEDs DL1 and DL2 have the function of informing the installer of the state the control unit is in.
DL1 and DL2 flash
alternately
DL1 and DL2 on permanently
DL1 off and DL2 flashing
DL1 on and DL2 off
DL1 flashes very fast
DL3
DL4
DL5
DL6
• Simultaneously press the two buttons P1 and P2 on the control unit and hold them down (MEMORY RESET). The
LEDs DL1 and DL2 come on permanently and then go off to indicate that the memory reset procedure has been
completed and that the gate-closed position has been determined. When the two buttons are released the LEDs
DL1 e DL2 flash alternately.
• To make the subsequent programming phase easier, it is recommended to let the control unit or the receiver learn one
remote control (see code learning). Otherwise, to execute programming a START command must be given by closing the
contact on terminals 3-4.
• To enable deceleration, DIP3 must be set to ON before starting programming.
Turn clockwise to increase the anti-crushing operating force MOTOR 1.
Turn clockwise to increase the anti-crushing operating force MOTOR 2.
The run time has not been programmed.
DIP1 is ON and time programming is in progress
Only the pedestrian run time has been programmed.
TX self-learning is in progress. In the version code AS04260, if the control unit does
not have any TX stored, the first time self-learning is accessed, LED1 flashes 4 times to
indicate that no remote control has been stored. Subsequently it stays on permanently.
The control unit is receiving a recognised type of code but it has not been
self-learned.
PHOTO LED. During normal operation it must be on.
It goes off when the photocell range of action is interrupted.
START LED. When it is on it indicates the presence of the start command on
the terminal board, or that the button P2 has been pressed.
STOP LED. When the control unit is in operation it must be on.
It goes off only when a stop command is given.
PEDESTRIAN START LED. When it is on it indicates the presence of the
pedestrian start command on the terminal board.
F12 RALLY