GiBiDi F 12 Rally Manual Del Usuario página 17

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 46
17
F12 RALLY
UK
TIME PROGRAMMING
(run time, pause time and wing phase shift time)
The first time the control unit is connected, it must self-learn the run times.
As long as the times have not been programmed, the Start key functions only with dead man's logic to move first wing
2 in slow motion during closing up to its limit switch and then wing 1 up to its limit switch. During this operation the Stop
and the photocells are ignored.
WARNING:
- the mechanical end-stops must be used;
- the timeprogramming logic requires that motor 2 arrives before motor 1 at the mechanical closing stop.
.
IMPORTANT: Always start this phase with the gate completely closed.
Position DIP1 to ON to start programming: the LEDs DL1 and DL2 come on and the control unit will emit some
BEEPS to indicate the number of cycles set for maintenance (see dedicated paragraph).
• Press Start: wing 1 starts opening and after 2 seconds wing 2
• When wing 1 arrives against the mechanical opening stop it halts (in the absence of the mechanical stop, press
Start to stop wing 1 in the desired position).
WING 1 STOPS
• When wing 2 arrives against the mechanical opening stop it halts (in the absence of the mechanical stop, again
press Start to stop wing 2 in the desired position).
WING 2 STOPS
• The control unit starts counting the pause time (max. 90 seconds)
• When the desired pause time has elapsed, press START
WING 2 STARTS CLOSING
• The control unit starts counting the phase shift time (max. 20 seconds)
• When the desired phase shift time has elapsed, press START
WING 1 STARTS CLOSING
• The control unit does not accept any further commands until both wings have stopped, which occurs when they
have reached their respective mechanical closing stops.
• Set DIP1 to OFF.
If the programming operation was not successful because of the anti-crushing device cutting in, turn the trimmers
RV1 and RV2 clockwise,
reset DIP1 to ON, and repeat the programming operation (the memory does not have to be reset). Should the gate
remain open without the
run time having been stored, it can be moved to the closing position by pressing and holding down the START button.