U
I
1
Test
1
Testing battery elements in short-circuit
2
Recovering damaged elements from an extended deep discharge
3
Sulphated battery test
4
Sulphated battery recovery
5
Checking the battery recovery
6
Battery charged to 80%
7
Battery charged to 100%
8
Maintenance charge
9
Starts a charge cycle for maintaining performance = maintenance
To save and confirm the new settings, select "EXPERT SETTING" | save? Yes"
Push the «MODE» key to exit the «Configuration» menu.
PROTECTIONS
This device is protected against short-circuits and polarity inversions. It has an anti-spark feature which prevents sparks whilst
connecting the Gysflash to the battery. The Gysflash will not deliver current if there is no battery detected (no voltage in the clamps).
The charger is fitted with an internal 80A fuse (ref. 054653), to protect against misuse.
TROUBLESHOOTING
TR O UB L ESH O O TI N G
Screen flashing :
1
« #error (+)<-->(-) »
+ alarm beep
Screen flashing :
« #error U>8V » or
2
« #error U>16V » or
« #error U>31V »
+ alarm beep
Screen flashing :
« #battery error »
3
+ alarm beep
18
GYSFLASH 50-12 HF / 50-24 HF
U=U
recovery
Recovery
2
3
4
Sulphation
CC Recovery
Desulphation
Test
C AUSES
The polarity has been reversed on the clamps
Battery voltage too high
Battery short-circuited or damaged
Battery not connected or clamps in short-circuit
6V Battery connected
U=U
Phase I
Phase U
I=I
charge
5
6
7
Test
Charge
Absorption
MODE
Connect the red clamp to the (+) and the black clamp to the (-) of the battery.
Charger not suitable or configured in 6V for a 12V/24V battery.
Charger not suitable or configured in 12V for a 24V battery.
Change the battery.
Check clamps connection.
Charger not suitable.
charge
U=U
oating
Phase U
0
8
9
New charge
Floating
cycle
R EM ED I ES
EN