If you need to change the voltage or network where the switch learned, reset the
switch according to the menu (37 RESET MENU), remove the switch from the
mains, wait for a few seconds and then turn it on again.
Each time the switch is reset, it will do the learning again.
• The switch must find the opening limit switch to start learning, the opening limit
switch is the first limit switch triggered during the limit switch setting process.
• After finding the opening limit correctly, the switch will start the learning cycle
according to index 5.
4. Operate the Central, with the Remote Control previously registered and obser-
ve the movement of the gate.
5. The switch will start a learning cycle by performing 3 or 4 drives automatically
(depending on the initial position of the drive nut).
6. During learning we advise not to press the remote control, otherwise the con-
trol panel will start the learning cycle again (except in emergencies).
7. Make sure that the stops are well adjusted, because if the engine wires are
incorrectly connected, when the stop is found, the control unit will automatically
adjust to the correct direction.
8. After activation of the remote control, the control panel will learn the route, then
the control panel will automatically learn the torque required to move the gate by
performing automatic opening and closing cycles.
9. At the end of the learning, the gate should be in the fully closed position, othe-
rwise reverse the direction of the limit switches by turning the PROG switch to the
position according to the table below and pressing LEARN one time.
PROG SWITCH POSITION
1 time
REVERSE DIRECTION
4 times
-
By pressing the LEARN button the LED next to the PROG switch will flash 5
times indicating that the direction has been successfully changed, then turn the
PROG switch to position 0 (RUN mode), and continue the desired settings.
PROGRAMMING
ENGINE DIRECTION
LED BLINKS
2 times
-
5 times
REVERSED
INGLÊS
3 times
-
-
-
65