Possible PAPR unit / compressed airline systems combinations
CleanAIR® AerGO®
CleanAIR® Chemical 2F
TH2
CleanAIR® Basic EVO
CleanAIR® Pressure Flow Master
TH2
12. Figures Annex
40 50 40
TH2
Spare parts
Headband
2B
70 29 41
Headband adjustment
Standard seal
Airduct
71 04 50CA
70 20 60
Screw set
Flip-up welding visor
70 29 42
70 29 45
Important
Please read and remember the following instructions before use to assure your own safety. If you have
any questions, please contact the manufacturer or your distributor.
Keep the manual for future reference. The welding hood should be used only for the purposes listed in
this manual.
1. Introduction
There are two main variants of product - welding hood Evermatic Evolve (hereinafter Evermatic Evolve)
and welding hood CA-29 Evolve (hereinafter CA-29 Evolve). Welding hood Evermatic Evolve is the basic
variant of the product, certified according to EN 166:2001 a EN 175:1997-08. It provides protection against
harmful ultraviolet / infrared radiation, welding spatters and high speed particles (indicated: A). Welding
hood CA-29 Evolve represents the improved version of welding hood Evermatic Evolve and is adapt-
ed for use with powered air purifying respirators (hereinafter PAPR) CleanAIR® or with continuous flow
compressed air line breathing apparatuses (hereinafter "compressed air systems CleanAIR®) and thus
provides protection of the respiratory tract. The variant CA-29 Evolve is additionally certified according to
EN 12941:1998+A2:2008 and EN 14594:2005.
CleanAIR® is a system of personal respiratory protection based on the principle of overpressure of filtered
air in the breathing zone. The respirator is placed on the wearer's belt and filtrates the air which is taken
in from the surrounding environment and then delivers it through the airduct into the protective hood.
The overpressure prevents contaminants from entering the breathing zone. This mild overpressure at
the same time ensures the wearer's comfort, even with long-term use, as the wearer does not have to
struggle in their breathing to overcome the resistance of the filter.
2. Limitations on use
Limitations for Evermatic Evolve and CA-29 Evolve
1. If work requires a protection against fast flying objects at extreme temperatures make sure that
visor has an marking T on it.
2. Material of the hood can cause allergic reactions to sensitive person.
3. Do not use tempered mineral filters without suitable protection foils.
4. The welding arc damages unprotected eyes!
5. The welding arc may burn unprotected skin!
6. Pay attention to checking the product before use.
Do not use, if any part of the system is damaged.
7. Don't put the welding hood on hot surface.
Additional limitations for CA-29 version
1. Never use the hood in the following environments and under the following conditions:
•
If oxygen concentration in the environment is lower than 17 %.
•
In oxygen-enriched environments.
•
In explosive ambience.
•
In environments where the user lacks knowledge about the kind of dangerous substance and its
concentration.
•
In environments that represent an immediate threat to the life and health.
•
If you are not sure, that shade number of your welding filter lens is suitable for your work.
•
Replace protection filter immediately, if it is damaged, or if spatter or scratches reduce vision.
•
The hood does not protect against hard shocks, explosions or corrosive substances.
2. Move to a secure location and take appropriate measures when any of the following problems occur
while using the hood:
•
If you feel significant increase of breathing resistance or any other problems with breathing.
•
If you experience stench or irritation or an unpleasant taste while breathing.
•
If you feel unwell or if you experience nausea.
3. Use certified original filters designed for your powered air purifying respirator only. Replace filters every
time you detect change of odour in supplied air from the respirator.