Dometic MagicWatch WPS 900F Manual Del Usuario página 21

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 73
WPS900F/WPS910
Programming functions
You can also set the function for the front sensors by programming it once, using the
following method, among others (see fig. i):
I
NOTE
The default settings are printed in bold in the table fig. i.
• Parameter 1: Speed signal/time-out front sensors (function 13 – 16)
Default setting: speed-dependent
Function 13 (speed-dependent) is set by default. If there is no speed signal avail-
able which is compatible, you have the alternative of using the time-out to deac-
tivate the front parking aid. Once activated, the programmed time period starts
counting down.
If there is an obstacle in the detection range when the time period is over, the
front parking aid remains active. Only when no obstacle is detected for more
than 5 s will the front parking aid shut down.
• Parameter 2: Duration of the front sensor signal
Default setting: 1 sec.
• Parameter 3: Choose the speed signal source
Default setting: Control unit
• Parameter 4: Detection range of the inner front sensors
Default setting: 80 cm
• Parameter 5: Detection range of the inner rear sensors
Default setting: 160 cm
• Parameter 6: Detection range of the outer front sensors
Default setting: 55 cm
• Parameter 7: Detection range of the outer rear sensors
Default setting: 55 cm
• Parameter 8: Stop zone for front sensors
Default setting: Corner sensors = 25 cm, middle sensors = 35 cm
• Parameter 9: Stop zone for rear sensors
Default setting: 35 cm
• Parameter 10: Volume of warning tones for front sensors
Default setting: High
• Parameter 11: Volume of warning tones for rear sensors
Default setting: High
EN
Setting the system
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Magicwatch wps 910

Tabla de contenido