DRAINING CONDENSATION BUILDUP
If the unit emits 8 beeps and displays H8 on the control panel, unplug the unit and wheel
it outdoors or in another area suitable for water drainage. Remove the rubber plug from
the drainage hose and allow the water to drain; replace the plug and reinstall the unit.
Note: the unit will restart after the compressor has been stopped for at least 3 minutes.
CLEANING THE OUTER HOUSING AND INTAKE GRILLE
If dust has accumulated on the unit, use a soft, dry dusting towel to wipe it off. If grease or
other harder to remove substances is on the unit, use a wrung-out cloth dampened with
warm, soapy water. Use a soft brush to clean off the grille.
CLEANING THE FILTER
For energy efficient operation, your filter
should be cleaned every three months.
Units in dusty environments may require
more frequent cleaning.
The front filter cover rests on a bot-
tom hinge and swings down. Open by using pulls on either side of the cover.
Remove the filter by gently tugging on it.
Use a vacuum cleaner or run cold water onto the filter to clean it. If the filter is
particularly dirty (such as grease buildup), wash and gently scrub the filter in a
bath of warm soapy water. Let the filter completely dry in a shady place; exposing
the filter to direct sunlight can cause deformation.
After the filter is clean and completely dry, re-insert the filter by pressing firmly
without forcing.
Note: To avoid deformation and fire risk, never dry the filter with a heat source, such as a
hair dryer, fireplace, or heater.
CLEANING THE HEAT EXHAUST DUCT
Disconnect the heat exhaust duct from the unit. Clean using warm, soapy water. Com-
pletely dry the parts and reconnect the duct.
TROUBLESHOOTING
PROBLEM / POSSIBLE CAUSES
The air conditioner does not function at all
• Is the power cable properly inserted into a functioning, grounded outlet?
• Is there a power failure such as a blown fuse or tripped circuit breaker?
• Is the timer set to "TIMER ON" mode? Disable the timer to immediately start operations.
• Is the internal collection tank or partition drain full/blocked and the FULL light
illuminated? Empty the tank.
• Is the ambient temperature lower than 61°F (16°C)? A safety device prevents the
unit from cooling the room to even lower temperatures.